137
4-6-20 MAINTENANCE OUT
T2
T2
T1
SYSTEM STANDBY OUT (Y7)
WARNING OUT (Y14)
MAINTENANCE OUT (Y13)
ALARM OUT (Y15)
*1
*2
ON
ON
OFF
ON (Normal)
OFF (Error)
ON
OFF
ON (Normal)
OFF (Error)
OFF
Maintenance criterion
Operating time
or
Number of operations
*1 : When the maintenance criterion operating time or number of operations is reached, MAINTENACE OUT turns ON.
*2 : Entering the maintenance complete on the maintenance screen in Laser Marker NAVI smart, resets the operating time
or number of operations.
Item
Time
Remarks
T1
Max. 1 sec.
It takes max. 1 sec. from the instant when the operating time or the number of operations
of a part subject to maintenance reaches the maintenance criterion to the instant when
MAINTENACE OUT (Y13) turns ON.
T2
Max. 10 sec.
Time for system startup. If there is any part whose operating time or number of
operations has reached the maintenance criterion at the time of startup of the laser
marker, MAINTENACE OUT (Y13) turns ON simultaneously with turning ON of
SYSTEMSTANDBY OUT (Y7).
ンㄆㄇㄆㄓㄆㄏㄆ
• The ON/OFF status of MAINTENANCE OUT (Y13) does not affect READY OUT (Y5).
• When “Laser pumping time [h]” and “Number of shutter open/close operations” reach the maintenance time, our service
staff will handle maintenance and replacement. Contact our sales agency.
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......