132
4-6-15 Counter reset input
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T5
T1
T2
T3
T1
T4
SELECT 0 - 2 IN (No.19-21)
D0 - D15 IN (No.3-18)
SET IN (No.2)
*1
*2
TRIGGER IN (X5)
READY OUT (Y5)
PROCESSING OUT (Y10)
SET OK OUT (No.28)
Item
Time
Remarks
T1
2ms or more
Keep the ON status for 2ms or more.
T2
0ms or more
Keep the input until SET OK OUT (No.28) turns on.
T3
2 to 510ms
One-shot output. Set the output time on the system settings screen. There is a small
margin of error for the setting value.
T4
0ms or more
Turn on TRIGGER IN (X5) after SET OK OUT (No.28) turns on.
T5
0.5ms or more
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN to
D15 IN, turn on SET IN (No.2).
*1 : To reset the counter, set SELECT 0 IN to SELECT 2 IN as follows.
SELECT 0 IN (No.19): OFF, SELECT 1 IN (No.20): OFF, SELECT 2 IN (No.21): ON
*2 : Specify the counter number to reset by using D0 IN to D15 IN (No.3 to 18). The following counter numbers are
assigned to D0 IN to D15 IN respectively.
• D0 to D3: Counter No. 0 to 3
• D4 to D7: Common Counter No. 16 to 19
• D8 to D11: Counter No. 4 to 7
• D12 to D15: Common Counter No. 20 to 23
ンㄆㄇㄆㄓㄆㄏㄆ
• If the counter is reset during on-the-fly marking operation, READY OUT (Y5) turns off momentary and there is a case
that the next marking could not be executed due to Warning E751.
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......