background image

 

 
 

 

 

 

Paddle-Type Flowmeter 
for Liquids

  

 

 

 

TSK 

 

 
 

Installation and Operating Instructions 
 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Heinrichs TSK

Page 1: ...Paddle Type Flowmeter for Liquids TSK Installation and Operating Instructions ...

Page 2: ...3W2 angle of rotation transmitter 6 6 CHARACTERISTIC VALUES 6 6 1 Accuracy 6 6 1 1 Reference conditions 6 6 1 2 Measured error 6 6 1 3 Repeatability 6 6 2 Influence of ambient temperature 6 6 3 Influence of fluid temperature 6 7 CONDITIONS OF USE 6 7 1 Installation conditions 6 7 1 1 Mounting start up 7 7 1 2 Device settings 7 7 1 3 Adjusting the limit transducer 7 7 1 4 Operation in hazardous are...

Page 3: ...r KINAX 3W2 transmitter with 4 20 mA output 2 wires 17 9 6 Wiring diagram for KINAX 3W2 transmitter with 4 20 mA output 3 wires 17 9 7 Wiring diagram for KINAX 3W2 transmitter with 4 20 mA output 4 wires 18 9 8 Wiring diagram for KEM 1 and KEM 2 double throw microswitches 18 10 INDICATOR UNIT 19 11 AUXILIARY POWER 19 12 CE MARK 19 13 ORDER INFORMATION 19 13 1 Available accessories 19 14 STANDARDS ...

Page 4: ...rrent flow rate in volume or mass per unit in time Applications flow measurement dosing monitoring adjusting and control of liquid and gaseous products The meter s design makes it ideal for processes under difficult and adverse operating conditions The devices are available with additional electrical equipment for process monitoring and control 3 Operational mode and system design 3 1 Measuring pr...

Page 5: ...oswitches whose switching point is activated by a cam plate KEM 1 1 Double throw microswitch KEM 2 2 Double throw microswitches Maximum make break capacity 230 VAC 50 60Hz 6 A 24 VDC 0 5 A 110 VDC 0 2 A 5 2 Analog output with the ES magneto electric transmitter The magneto electric transmitter is factory calibrated to the scale values upon shipment The signal output is supplied exclusively in a tw...

Page 6: ...ges in viscosity cause a non linear display fault 7 Conditions of use The VDI VDE guidelines 3513 Sheet 3 must be observed The meter is suitable for Liquids with sufficient flowability that are free of solids do not bond and do not tend to settle For paddle type devices viscosity factors must not be considered physically They do not play any role or play an insignificant role when the flow rates a...

Page 7: ...ions The gaskets must be suitable for the operating pressure the temperature and the measured medium With PTFE and PP coated devices use gaskets whose interior and exterior diameter correspond to the sealing strip of the device Tighten the flange bolts crosswise so that the process connections are tight Pay particular attention to the tightening torques of screws especially with PTFE and PP coated...

Page 8: ... T6 T4 7 1 4 2 2 Marking for the device when the ES magneto electric transmitter is built in DMT 00 ATEX 075 II2G Eex ia IIC T6 7 1 4 2 3 Marking for the device when the KINAX 3W2 angle of rotation transmitter is built in PTB 97 ATEX 2271 II 2G Eex ia IIC T6 7 1 4 3 Atmospheric conditions In accordance with EN 1127 a potentially explosive atmosphere is defined as a mixture of air and combustible g...

Page 9: ... 40 C or rises above 200 C The effect of the fluid temperature on the indicator unit and its built in components must be considered 7 3 2 Diagram Max ambient temperature based on the fluid temperature for the built in sensor Type ES 20 25 30 35 40 45 50 55 60 65 70 70 80 90 100 110 120 130 140 150 160 170 180 190 200 fluid temperature C Max ambient temperature C 7 3 3 Fluid pressure limit TSK1 C D...

Page 10: ...ing stainless steel Paddle axis spring stainless steel Indicator unit aluminum and safety glass window TSK1 K Fitting PP Paddle axis spring stainless steel option Hastelloy Indicator unit aluminum and safety glass window TSK1 P Fitting PTFE Paddle axis spring Hastelloy option titanium Indicator unit aluminum and safety glass window 8 4 Dimension table for TSK1 C and TSK1 S The corresponding dimens...

Page 11: ...chs Messtechnik TSK1 Installation and Operating Instructions Page 11 of 27 8 5 Dimension drawings 8 5 1 Aluminum indicator unit Flow measurement from left to the right Flow measurement from right to the left ...

Page 12: ...Heinrichs Messtechnik TSK1 Installation and Operating Instructions Page 12 of 27 Direction of flow from the top to the bottom Direction of flow from the bottom to the top ...

Page 13: ...Heinrichs Messtechnik TSK1 Installation and Operating Instructions Page 13 of 27 8 5 2 Stainless steel indicator unit Flow measurement from left to the right Flow measurement from right to the left ...

Page 14: ...Heinrichs Messtechnik TSK1 Installation and Operating Instructions Page 14 of 27 Direction of flow from the top to the bottom Direction of flow from the bottom to the top ...

Page 15: ...r remove the indicator cover insert the connector cable into the cable gland and attach it to the terminals according to the terminal diagram Tighten the cable gland securely remount the indicator cover and close it tightly 9 1 Wiring diagram for ES transmitter 9 2 Wiring diagram for ES transmitter with 4 20 mA output and 2 limit transducers ...

Page 16: ...esstechnik TSK1 Installation and Operating Instructions Page 16 of 27 9 3 Wiring diagram for ES transmitter with 4 20 mA output pulse output and limit transducer 9 4 Wiring diagram for inductive limit transducers ...

Page 17: ...sstechnik TSK1 Installation and Operating Instructions Page 17 of 27 9 5 Wiring diagram for KINAX 3W2 transmitter with 4 20 mA output 2 wires 9 6 Wiring diagram for KINAX 3W2 transmitter with 4 20 mA output 3 wires ...

Page 18: ... Messtechnik TSK1 Installation and Operating Instructions Page 18 of 27 9 7 Wiring diagram for KINAX 3W2 transmitter with 4 20 mA output 4 wires 9 8 Wiring diagram for KEM 1 and KEM 2 double throw microswitches ...

Page 19: ...the device in hazardous areas follow the applicable national installation rules 15 2 Installation start up and operating personnel Only trained specialists authorized by the system operator may carry out the installation electrical installations startup maintenance and operation They must read and understand the operating manual and follow its instructions The required mounting electrical installa...

Page 20: ...ot move If the pointer is unable to move further send the device to the head office for servicing Electrical equipment are not functioning Check the auxiliary power Are suitable power supply equipment connected have the terminals been selected correctly has the parameterization carried out correctly 19 Returning devices for repair and service Note In accordance with the applicable German waste dis...

Page 21: ...g the measured medium Since this measured medium is dangerous in water poisonous corrosive flammable we have checked that all hollow spaces of the device are free of these materials neutralized and flushed all hollow spaces of the device cross out what is not applicable We hereby confirm that in resending the device no danger to persons or the environment is posed by the residual measured substanc...

Page 22: ...Heinrichs Messtechnik TSK1 Installation and Operating Instructions Page 22 of 27 22 EC Type Examination Certificates ...

Page 23: ...Heinrichs Messtechnik TSK1 Installation and Operating Instructions Page 23 of 27 ...

Page 24: ...Heinrichs Messtechnik TSK1 Installation and Operating Instructions Page 24 of 27 ...

Page 25: ...Heinrichs Messtechnik TSK1 Installation and Operating Instructions Page 25 of 27 ...

Page 26: ...Heinrichs Messtechnik TSK1 Installation and Operating Instructions Page 26 of 27 ...

Page 27: ...Heinrichs Messtechnik TSK Installation and Operating Instructions Seite 27 von 27 23 Sales representatives Internet http www heinrichs eu 24 Notes ...