3.
Remove the two connectors of the fans on the controller. (One connector for
one fan)
4.
Loosen the M4 nuts (4 nuts for 1 fan) with hexagonal
nut driver, and remove the fan guard and the fan
itself from the controller.
WARNING
• Do not drop the fan mounting nut inside the controller. It may short-circuit the
internal circuits and cause accident or malfunction.
5.
Remove dust and dirt adhered onto the fan by air-blowing.
ワㄐㄕㄊㄆ
• Do not rinse the fan. This may cause failure of the electronic parts inside.
Connector
Fan
Fan guard
Nut