INSTALLATION PROCEDURE

1. Physically mount the Smart-VS device.

2. Make the necessary electrical connections.

3.

Configure the device using the embedded HMI or

the Smart-VS WebApp by connecting to the device

via Ethernet. The WebApp is accessible opening an

Internet browser (Google Chrome is recommended)

and entering the device IP address 192.168.3.100

in the address bar.

HMI INTERFACE

NO GOOD object

in  Teach  phase:  blinking,  NO  GOOD  object

teaching

in Run phase: NO GOOD object detected

• for future use

Trigger

• in Teach phase: trigger input status

• in Run phase: trigger received

GOOD object

in  Teach  phase:  blinking,  GOOD  object

teaching

in Run phase: GOOD object detected

Run

• steady: device in Run phase

• blinking: Teaching required

BUTTON TEACHING PROCEDURE

The Run LED will blink until the Teaching procedure is 

entered (e.g. device factory default).

Long press (> 4s, until the red LED on HMI lights up) 

the HMI Button to enter the Teaching procedure.

1.

GOOD objects required to be

taught (green LED and green

spot blink).

2.

Place  the  GOOD  object  in

front of the Aiming System.

3. Place the trigger sensor

properly. The Trigger LED

indicates object detection.

4. Short  press  (<  1s)  the  HMI

Button  to  acquire  the  image.

More  than  one  GOOD

object  can  be  acquired.    It

is suggested to acquire one

image  per  GOOD  object

instance. Camera parameters

are  auto-adjusted  on  the  first

acquisition only.

5.

Long press (

> 4s, until the red

LED  on  HMI  lights  up

)  the

HMI  Button  to  start  acquiring

NO  GOOD  objects.  Red  LED

and red spot start blinking.

6. Place  the  NO  GOOD  object

in front of the Aiming System.

Check the Trigger LED.

7.

Short  press  (<  1s)  the  HMI

Button  to  acquire  the  image.

More  than  one  NO  GOOD

object can be acquired.

8. Long  press  (

>  4s,  until  the

red  LED  on  HMI  lights  up

)

the  HMI  Button  to  enter  the

automatic learning procedure

(LEDs  game).  At  the  end,

the device will enter the Run

Phase.

The Teaching procedure can also be 

entered when in Run phase: press the 

HMI Button for 2s (yellow LED on HMI) for 

incremental teaching or 4s (red LED on 

HMI) to cancel and re-teach. Refer to the 

Product Reference Guide for more details.

NOTE

1

2

3

4

6

7

5

11

8

9

10

1.

Bracket Mounting Holes (2)

2. Power On LED

3. Ethernet Connection LED

4. 90° Rotating Connector Block

5.

HMI Interface

6.

Ethernet Connector

7.

Power - I/O Connector

8.

Lens

9.

LED Aiming System

10. Red Spot (NO GOOD)

11. 

Green Spot (GOOD)

12. 

White Polarized Illuminators

M12 17-pin Power, and I/O Connector Pinout 

(9 stripped wires)

Pin

Color

Name Function

1

2

Brown

Blue

Vdc

GND

PWR supply input v

PWR supply input voltage -

Connector 

case

Chassis Connector case provides 

electrical connection to 

chassis

6

5

13

3

Yellow

Pink

Green

White

I1A *

I1B *

I2A *

I2B *

Trigger Input A
Trigger Input B

Remote Teach A

Remote Teach B

9

Red

O1 **

Data Valid (default is Push-

Pull)

8

Gray

O2 **

GOOD  Output  (default  is 

Push-Pull)

16

Black

O3 **

NO-GOOD  Output  (default 

is Push-Pull)

*

Polarity insensitive

** 

Short-circuit protected and

    software programmable

12

For proper installation, it is recommended 

to trim out all unused wires.

WARNING

M12 17-pin Power, and I/O Connector Pinout 

(17 stripped wires)

Pin

Color

Name Function

1

2

Brown

Blue

Vdc

GND

PWR supply input v

PWR supply input voltage -

Connector 

case

Chassis Connector case provides 

electrical connection to 

chassis

6

5

13

3

Yellow

Pink

White/Green

White

I1A *

I1B *

I2A *

I2B *

Trigger Input A
Trigger Input B

Remote Teach A

Remote Teach B

9

Red

O1 **

Data Valid (default is Push-

Pull)

8

Gray

O2 **

GOOD  Output  (default  is 

Push-Pull)

16

Yellow/Brown

O3 **

NO-GOOD  Output  (default 

is Push-Pull)

CAB-GD03 M12-17P 3M power and 

I/O cable, isolated wires (95A900052)
CAB-GD05 M12-17P 5M power and 

I/O cable, isolated wires (95A900053)

CAB-GD03 M12 F/L 3M Free wires

CAB-GD05 M12 F/L 5M Free wires

CAB-GD10 M12 F/L 10M Free wires

Reviews: