2
Installa
tion
2-31
10. Installing the tool flange
A tool flange can be installed later on the R6YXGLC(P)250, R6YXGLC(P)350, R6YXGLC(P)400, R6YXGLC(P)500
and R6YXGLC(P)600 models.
The following option parts are needed.
No.
Part No.
Q'ty
Remarks
1
KCY-M1790-000
1
Tool flange
2
91312-05014
2
Bolt
3
92A08-05308
1
Set screw
1
Turn off the controller.
2
Place a sign indicating the robot is
being adjusted.
Place a sign indicating the robot is being adjusted, to
keep others from operating the controller and
operation panel.
3
Enter the safety enclosure.
4
Install the tool flange.
Align the orientation of the tapped hole for the tool
flange set screw with that of the width across flat
part of the spline, and then insert the tool flange all
the way inside.
Tool flange (1)
Set screw (3)
Width across flat part
Degrease these
portions.
Bolt (2)
Installing the tool flange
Step 4-6
5
Install the tool flange with the bolt (2).
Secure the tool flange after it has been inserted all
the way inside.
• Tightening torque: 9Nm (92kgfcm)
Apply the grease to the bolt thinly to make the
tightening torque stable.
6
Tighten the set screw (3).
• Tightening torque: 3.5Nm (36kgfcm)
Apply Loctite 262 (Henkel Japan) to the set screw.
7
Go out of the safety enclosure.
Summary of Contents for R6YXGLC250
Page 1: ...ZX T Series Cat No I158E EN 02A R6Y XGC XGP series INSTALLATION MANUAL SCARA Robots XG Series...
Page 2: ......
Page 8: ......
Page 34: ......
Page 36: ......
Page 38: ......
Page 42: ......
Page 44: ......
Page 50: ......
Page 86: ......
Page 91: ...Chapter 4 Periodic inspection Contents 1 List of inspection items 4 1...
Page 92: ......
Page 95: ...Chapter 5 Harmonic drive replacement period Contents 1 Overview 5 1 2 Replacement period 5 2...
Page 96: ......
Page 100: ......
Page 104: ......
Page 106: ......
Page 135: ......