6-29
6-4 Setting the Mode
Opera
tion
6
3. Returning to Copy Mode
Copying from the Parameter Unit to the Servo Drive
1. Displaying Copy Mode
2. Checking the Servo Drive Model Code
Key
operation
Display example
Explanation
Press the
key to return to Copy Mode.
If
is displayed before completion, repeat the procedure from the
beginning. Press the
key to clear the error.
Do not disconnect the Parameter Unit from the Servo Drive while copying
is being performed. If the Parameter Unit is disconnected, connect it and
then repeat the procedure from the beginning.
If errors are repeatedly displayed, the following may be the cause: cable
disconnection, connector contact failure, incorrect operation due to noise,
or EEPROM fault in the Parameter Unit.
Key
operation
Display example
Explanation
The item set for the Default Display (Pn001) is displayed.
Press the
key to display Monitor Mode.
Press the
key five times to display Copy Mode.
Press the
key to switch to the copy display for copying from the Param-
eter Unit to the Servo Drive.
Key
operation
Display example
Explanation
Press the
key to switch to Copy Mode.
Press and hold the
key until “EEP_CH” is displayed.
If the model codes do not match, "DIFFER" will be displayed.
The bar indicator will increase when the key is pressed for 3 s or longer.
The bar indicator will increase.
The Servo Drive model code is being checked. If a different model code has
been entered, refer to 3. Different Model Codes on the next page to perform
the procedure.
If the model codes match, the display will proceed to the display in 4. Execut-
ing Copying.
Precautions
for Correct Use