5-57
5-26 User Parameters
Ope
rati
n
g Func
tions
5
Operating Procedures for 32-bit Positioning Parameters
1. Displaying Parameter Setting Mode
2. Selecting the Parameter Type
3. Switching to the Parameter Setting Display
4. Setting the Parameter Number
5. Displaying the Parameter Setting
Key
operation
Display example
Explanation
The default display is displayed.
Press the
key to display Monitor Mode.
Press the
key to display Parameter Setting Mode.
Key
operation
Display example
Explanation
Press the
keys to select 32-bit parameters.
Key
operation
Display example
Explanation
Press the
key to go to the Parameter Setting Display.
Press the
key to return to the Parameter Type Selection Display.
Key
operation
Display example
Explanation
Set the number of the parameter to be set or checked.
Key
operation
Display example
Explanation
Press the
key to display the setting.
The selected parameter number appears in the sub window.
32-bit parameters have many digits and thus displayed on two displays.
Press the
key to change the display.
Negative values of the parameter are indicated with a dot.
Uknk_k5kpkd
1k6kbkiktkp
3k2kbkiktkp
pknk_krk0k0.k
3k2
pknk_krk0k5.k
3k2
k k6k3k2k8.
0k0
Hk k k k k
0k0