Adaptive Filter Table
The table number corresponding to the frequency for the adaptive filter is displayed.
This parameter is set automatically and cannot be changed when the adaptive filter is enabled
(when the Adaptive Filter Selection (Pn023) is 1 or 2).
When the adaptive filter is enabled, data will be saved in EEPROM every 30 min. If the adaptive
filter is enabled the next time the power supply is turned ON, adaptive operation will start with the
data saved in EEPROM as the default value.
To clear this parameter and reset the adaptive operation, disable the adaptive filter by setting the
Adaptive Filter Selection (Pn023) to 0, and then enable it again.
Pn02F Notch Filter 1 Frequency
Pn02F Notch Filter 1 Frequency
Pn02F
Notch Filter 1 Frequency
0
(Disabled)
22
766
44
326
1
(Disabled)
23
737
45
314
2
(Disabled)
24
709
46
302
3
(Disabled)
25
682
47
290
4
(Disabled)
26
656
48
279
5
1482
27
631
49
269 (Disabled when Pn022
≥
F)
6
1426
28
607
50
258 (Disabled when Pn022
≥
F)
7
1372
29
584
51
248 (Disabled when Pn022
≥
F)
8
1319
30
562
52
239 (Disabled when Pn022
≥
F)
9
1269
31
540
53
230 (Disabled when Pn022
≥
F)
10
1221
32
520
54
221 (Disabled when Pn022
≥
E)
11
1174
33
500
55
213 (Disabled when Pn022
≥
E)
12
1130
34
481
56
205 (Disabled when Pn022
≥
E)
13
1087
35
462
57
197 (Disabled when Pn022
≥
E)
14
1045
36
445
58
189 (Disabled when Pn022
≥
E)
15
1005
37
428
59
182 (Disabled when Pn022
≥
D)
16
967
38
412
60
(Disabled)
17
930
39
396
61
(Disabled)
18
895
40
381
62
(Disabled)
19
861
41
366
63
(Disabled)
20
828
42
352
64
(Disabled)
21
796
43
339