8-3
8-2 Alarm Table
Troubleshooting
8
8-2 Alarm Table
Protective Functions
The Servo Drive has built-in protective functions. When a protective function is activated, the
Servo Drive turns OFF the alarm output signal (ALM) and switches to the Servo OFF status.
The alarm code will be displayed on the front panel.
Warning Function
The Servo Drive issues a warning before a protective function is activated, allowing you to check
overload and other status in advance. A warning is also issued for a network error, allowing you
to check the network status.
Alarm type
Description
---
Protective function that allows the alarm to be reset, and leaves record in the
alarm history.
PR
Protective function that does not allow the alarm to be reset, and requires the
control power supply to be turned OFF and turned ON again after resolving the
problem.
X
Protective function that does not leave record in the alarm history.
Alarms can be reset via the network, CX-Drive or the Parameter Unit.
Overload (alarm code 16) cannot be reset for approximately 10 s after its
occurrence.
If "HH", "hh", or "yy" is displayed on the Alarm Number display, the built-in
MPU is malfunctioning. Turn OFF the power supply.
Precautions