2-10
Section
Graphs
145
The relationship between the properties of a bar graph and the display results is
indicated below.
Properties
General
Position
Coordinates of the top left corner of the bar graph area.
Size
Width and height of the area in which the bar graph is displayed
(dot units)
NT31/NT31C:
Width 2 to 230, Height 2 to 240
NT631/NT631C: Width 2 to 640, Height 2 to 480
Frame
Whether or not a frame is displayed for the graph area
Check mark (frame displayed)/
No check mark (frame not displayed)
Display Sign
Whether or not a negative area is displayed.
Check mark (displayed)/No check mark (not displayed)
Direction
Direction in which the bar graph extends (Incremental Direction
of Bar Graphs, page 147)
Up/Down/Left/Right
Color
Frame
Display color of the frame (Colors other than black and white are
available with the NT31C and NT631C only.)
Black/Blue/Red/Magenta/Green/Cyan/Yellow/White
+ Range
Display color of the positive range (Colors other than black and
white are available with the NT31C and NT631C only.)
Black/Blue/Red/Magenta/Green/Cyan/Yellow/White
– Range
Display color of the negative range (Colors other than black
and white are available with the NT31C and NT631C only.)
(effective only when a check mark is set for Display Sign)
Black/Blue/Red/Magenta/Green/Cyan/Yellow/White
Settings
Value
Table Entry
Number of numeral memory table whose contents are to be dis-
played.
Display %
Presence/absence of a percentage indication of the contents of
the numeral memory table (Method for calculating the percent-
age value, page 147)
Check mark (percentage displayed)/
No check mark (no percentage display)
For details on the Display % properties, refer to the
Text (Fixed
Display) on page 88.
100%
*1
(Specify 100% value using either of Table Entry or Value.)
Table Entry
Numeral memory table number checked to find the 100%
value for percentage calculations
@
Designate the number of the numeral memory table that
stores the 100% value.
Range: 0 to 1999
Value
Checked to find the 100% value for percentage calculations
@
Designate the 100% value (default: 100)
Range: –2147483648 to 2147483647
Reference:
The graph’s % values are always displayed with the standard display attributes.
These display attributes cannot be changed.
Common Attributes
electronic components distributor
Summary of Contents for NT21 Series
Page 3: ...iv Downloaded from Elcodis com electronic components distributor...
Page 5: ...vi Downloaded from Elcodis com electronic components distributor...
Page 463: ...Downloaded from Elcodis com electronic components distributor...
Page 465: ...Downloaded from Elcodis com electronic components distributor...