2-7
Section
Touch Switches
125
The attributes for the window key are as follows.
Settings
Screen No.
Local 1
(Keyboard)
Check this attribute when the local window 1 is to be
controlled.
S
Specify the screen number of the window to be
controlled.
1 to 3999
Local 2
Check this attribute when the local window 2 is to be
controlled.
S
Specify the screen number of the window to be
controlled.
1 to 3999
Window Position
X
X coordinate of bottom-left corner (multiple of 20)
NT31/NT31C: 0 to 300
NT631/NT631C: 0 to 620
Y
Y coordinate of bottom-left corner (multiple of 20 - 1)
NT31/NT31C: 19 to 239
NT631/NT631C: 19 to 479
Action Type
Controlling method of the window
Open/Close/Toggle
Replace Local
Window
Specify the behavior of the window when the other
window of the same type (Local 1/Local 2) is already
opened.
Check mark (replace)/No check mark (no replace)
The window behaves as follows according to the settings for Action Type and
Replace Local Windows.
Behavior According to The action Type
Open: Opens the specified window by the specified type (local 1 or local 2).
Whether or not the window is actually opened depends on the display
status and the setting for Replace Local Window.
The window is displayed at the position which is specified with the Win-
dow Position setting.
If the other window of the same type is already opened, the behavior is
determined according to the setting for Replace Local Window.
If the specified window does not exist, no operation is performed.
Close: Closes the specified window of the specified type (local 1 or local 2).
When the close window key is pressed, the specified window which is
presently displayed by the specified type is closed.
If the specified window is not displayed by the specified type, no opera-
tion is executed.
Toggle: Opens or closes the specified window of the specified type (local 1 or
local 2).
If the specified window is not displayed by the specified type, the speci-
fied window is opened in the same way as the Open window key.
Whether or not the window is actually opened depends on the display
status and the setting for Replace Local Window.
The window is displayed at the position which is specified with the Win-
dow Position setting.
If the other window of the same type is already opened, the behavior is
determined according to the setting for Replace Local Window.
If the specified window does not exist, no operation is performed.
If the specified window is already displayed by the specified type, the
window is closed in the same way as Close window key.
Behavior According to The Replace Local Window
Check mark:
If the other window of the same type is already displayed, the
displayed window is closed first, and then the specified window
is opened.
electronic components distributor
Summary of Contents for NT21 Series
Page 3: ...iv Downloaded from Elcodis com electronic components distributor...
Page 5: ...vi Downloaded from Elcodis com electronic components distributor...
Page 463: ...Downloaded from Elcodis com electronic components distributor...
Page 465: ...Downloaded from Elcodis com electronic components distributor...