Appendix B
Compatibility with Screen Data of Other PT Models
431
Item
NT31/NT31C, NT631/NT631C
NT30/NT30C, NT620S/NT620C/NT625C
PT status
notify area
Bit
Screen number (4 BCD digits)
Numeral/character string memory table number
(3 BCD digits)
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Word m
Word m+1
Word m+2
Word
0
0
0
0
PT status notify bits
0
PT status notify bits
0
0
0
Bit
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Word m
Word m+1
Word
Numeral/character string memory table number
(BCD or hexadecimal 4 digits)
PT status notify bits
Word
Notified Information
1 (ON)
0 (OFF)
15
PT operation status
Run
Stop
14
Not used
Always 0
13
Battery
Low
Normal
12
Screen switch strobe
ON
OFF
11
Numeral setting strobe
ON
OFF
10
Character string setting strobe
ON
OFF
9
Not used
Always 0
8
Not used
Always 0
7
Printer operating status
Printing
Stopped
PT status notify bits
Word
Notified Information
1 (ON)
0 (OFF)
15
PT operation status
Run
Stop
14
Not used
Always 0
13
Battery
Low
Normal
12
Screen switch strobe
ON
OFF
11
Numeral setting strobe
ON
OFF
10
Character string setting strobe
ON
OFF
9
Not used
Always 0
8
Not used
Always 0
7
Printer operating status
Printing
Stopped
6
Backlight status
OFF
Lit/flashing
5*
Global window open status
Open
Close
4*
Local window 1 open status
Open
Close
3*
Local window 2 open status
Open
Close
* : Added for V1
The contents of Screen number of the displayed screen (PT status
notify area word m in the NT30/NT30C, NT620S/NT620C/NT625C) is
written to PT status control area wordn.
Window
control
area
None
Word k+1
Bit
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Word k
Word
Global window
Screen No. (4-digit BCD or hexadecimal)
Global window
X coordinate (4-digit BCD or hexadecimal)
Global window
Y coordinate (4-digit BCD or hexadecimal)
Local window1
X coordinate (4-digit BCD or hexadecimal)
Local window1
Y coordinate (4-digit BCD or hexadecimal)
Local window1
Screen No. (4-digit BCD or hexadecimal)
Local window2
X coordinate (4-digit BCD or hexadecimal)
Local window2
Y coordinate (4-digit BCD or hexadecimal)
Local window2
Screen No. (4-digit BCD or hexadecimal)
Word k+2
Word k+3
Word k+4
Word k+5
Word k+6
Word k+7
Word k+8
Screen
display
0:
No display
1 to 1899:
Normal screens
1900 to 1979: Window screens, normal screens
1980 to 1996: Expansion functions, normal screens
1997:
Display history (occurrence order) screen
1998:
Display history (frequency order) screen
1999:
Connected to host screen
0:
No display
1 to 3999 :
Normal screens, window screens, overlapping screens
9000:
System Initializing screen
9001:
Display history (occurrence order) screen
9002:
Display history (frequency order) screen
9020:
Screen for programming console function
9021 to 9023: Device Monitor function
9999:
Return to the previous screen
Continu-
ous
screens
Possible
Not possible
A parent screen is deleted after the data conversion, such as from an
NT30/NT30C or NT620S/NT620C/NT625C to a NT31/NT31C or
NT631/NT631C.
Use a switch screen touch switch instead.
Overlap-
ping
screens
A window or keyboard screen
can
be specified as a child screen.
A window or keyboard screen
cannot
be specified as a child screen.
Initial
screen
Host connect screen
System initializing screen
electronic components distributor
Summary of Contents for NT21 Series
Page 3: ...iv Downloaded from Elcodis com electronic components distributor...
Page 5: ...vi Downloaded from Elcodis com electronic components distributor...
Page 463: ...Downloaded from Elcodis com electronic components distributor...
Page 465: ...Downloaded from Elcodis com electronic components distributor...