2-2
Section
Areas for Control/Notification
59
It is possible to know the screen number of the window which is currently open or
the display position (bottom-left coordinate) by checking the window control
area.
Strobes
The screen switching, numeral setting, and character string setting strobes are
automatically returned to 0 (OFF) after notification to the host. The status of op-
erations at the PT can easily be ascertained by detecting the leading edges of
these strobes.
However, when connected to a CVM1/CV series CPU, if the PC is set for
asynchronous operation, the leading edge may not be detected.
2-2-3 Window Control Area (Host
↔
PT)
Data is written to the window control area from both the PT and the host. The
status of the window is always written.
When the data is written to this area from the host, the PT reads the data and
display the window with the specified number at the designated position.
When the display status of the window (screen No., display position) is changed
due to the operation at PT, current status of the window is written to the area allo-
cated to the host. The host can determine the display status of the window by
reading this area.
The window control area is configured as nine consecutive words as shown be-
low. The first word (word k) is set in the Control/Notify Area settings in the PT
configuration settings made with the Support Tool.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit
Screen No. (4-digit BCD or hexadecimal)
X coordinate (4-digit BCD or hexadecimal)
Y coordinate (4-digit BCD or hexadecimal)
Screen No. (4-digit BCD or hexadecimal)
X coordinate (4-digit BCD or hexadecimal)
Y coordinate (4-digit BCD or hexadecimal)
Screen No. (4-digit BCD or hexadecimal)
X coordinate (4-digit BCD or hexadecimal)
Y coordinate (4-digit BCD or hexadecimal)
Word
k
k+1
k+2
k+3
k+4
k+5
k+6
k+7
k+8
Global window
Local Window1
Local Window2
Reference:
It is not necessary to allocate word to window control area when the window is not
controlled from the host or when the window is not used.
The window control area (PT (host) can be allocated to the following host (PC)
data areas.
Symbol
C-series PCs
Allocation
CV-series PCs
Allocation
CS1-series PCs
Allocation
None
IR Area
f
CIO Area
f
CIO Area
f
H
HR Area
f
---
---
HR Area
n
A
AR Area
f
Auxiliary Area
AR Area
f
L
LR Area
f
---
---
LR Area
*1
n
T
TC Area,
Timer PVs
Timer Area,
Timer PVs
TC Area,
Timer PVs
TU
---
---
---
---
TC Area,
Timer Completion Flags
C
TC Area,
Counter PVs
Counter Area,
Counter PVs
TC Area,
Counter PVs
Allocated Words of the
Window Control Area
electronic components distributor
Summary of Contents for NT21 Series
Page 3: ...iv Downloaded from Elcodis com electronic components distributor...
Page 5: ...vi Downloaded from Elcodis com electronic components distributor...
Page 463: ...Downloaded from Elcodis com electronic components distributor...
Page 465: ...Downloaded from Elcodis com electronic components distributor...