2-14
Section
Recipe
217
Support Tool
(1) Downloading
(3) Uploading
Flash memory
Recipe data memory
(Battery backup)
Updated data
(3) Overwriting
during upload-
ing
(1) Copying during downloading
or
(4) Copying during recipe table
initialization in the System Menu.
(2) Data transfer with PC
(2) Editing on PT
PT
PC
2-14-3 Limits
•
You can register a maximum of 1 recipe element per screen. You cannot regis-
ter recipe elements in window screens. If using 8 overlapping screens, you can
register a maximum of 8 recipe elements.
•
You can register a maximum of 200 recipes in one screen data file, to a recipe
data capacity of 40 Kbytes maximum. You can determine the recipe data ca-
pacity using the following formula.
Data capacity = Total parameter size x Number of records x Number of rec-
ipe data
You can specify parameter size as 1 word ( = 2 bytes) or 2 words ( = 4 bytes)
for each parameter separately.
•
The range of values that can be entered using the Support Tool is fixed at
–2,147,483,648 to 2,147,483,647 (regardless of settings such as storage type
and display method, which are explained below).
2-14-4 Common Attributes
The recipe table properties and recipe element properties are as follows:
electronic components distributor