![background image](http://html1.mh-extra.com/html/omron/nt21-series/nt21-series_reference-manual_744543392.webp)
4-3
Section
Commands/Responses
383
Command
0
1B
50
[ESC]
P
31
31
1
4D
M
1
31
30
1
0
30
1
31
30
0
0D
8
43
C
8
38
30
0
A
41
[CR]
38
First word number of PT notify area
: 110CH
Number of changed words in PT control area
: 1CH
PT status notify bit (hexadecimal)
: 8080
H
(PT operation status bit,
screen printing bit: ON)
Check sum
: AC
H
Reference:
When NT30/620 compatible mode is being used, the current screen number oc-
cupies the first word of the PT status notify area and the words containing the
updated memory table number and PT status notify bits are shifted down one
word.
Example 3. Notification of Change in The Window Control Area
Notification of change in the window control area is issued when a window is
controlled by the operation at the PT. It is possible to know the screen number of
the window which is opened and the display position of the window (bottom left
coordinate (X, Y) of the window). In the example below, it is ascertained that the
window screen No.16 is displayed at the position on X: 280, Y: 99.
Command
0
1B
50
[ESC]
P
32
30
0
30
0
4D
M
1
31
30
2
0
30
3
1
38
8
,
2C
31
1
1
31
2C
,
36
6
33
31
0D
3
41
A
9
39
[CR]
33
First word number of window control area
: 120CH
Number of changed words in window control area
: 3CH
Screen number (hexadecimal)
: 10H
(screen No.16 in BCD)
Window X coordinate (hexadecimal): 118H (280 in BCD)
Window Y coordinate (hexadecimal): 63H (99 in BCD)
Check sum
: 9AH
Reference:
S
With memory link communication, bit 12 (screen switch strobe), bit 11 (numer-
al setting strobe flag) and bit 10 (character string setting strobe flag) of PT sta-
tus notify bit do not go ON/OFF. It is possible to know them by direct area
changing notify command, numeral input notify command and character
string input notify command.
S
When the PT was switched to RUN mode from system menu or error screen,
notification of change in PT notify area (PT operation status: ON) is issued to
the host.
Also, when the PT was switched to system menu or error screen from RUN
mode, notification of change in PT notify area (PT operation status: OFF) is is-
sued to the host.
Contents of
direct area after
the change
electronic components distributor
Summary of Contents for NT21 Series
Page 3: ...iv Downloaded from Elcodis com electronic components distributor...
Page 5: ...vi Downloaded from Elcodis com electronic components distributor...
Page 463: ...Downloaded from Elcodis com electronic components distributor...
Page 465: ...Downloaded from Elcodis com electronic components distributor...