2-10
Section
Graphs
157
Settings (properties of each broken line)
Start Table
Entry
*1
First numeral memory table number of the numeral memory
tables used to display the broken line.
Range: 0 to 1998
No. of points
*1
Number of vertices in the broken line display (one memory table
is used for each vertex)
NT31/NT31C:
2 to 320
NT631/NT631C: 2 to 512
Interval Type
Interval between numeral memory tables in the broken line.
Even/Uneven (cannot resize) (0 to size in the broken line
graph Direction – 1)
Line
Color
Display color of the broken line (Colors other than black and
white are available with the NT31C and NT631C only.)
Black/Blue/Red/Magenta/Green/Cyan/Yellow/White
Style
Line type used for the broken line graph
Solid line:
Broken line:
1-dot chain line:
2-dot chain line:
100%
*2
(Specify 100% value using either of Table Entry or Value.)
Table Entry
Numeral memory table number checked to find the 100%
value for percentage calculations
@
Designate the number of the numeral memory table that
stores the 100% value.
Range: 0 to 1999
Value
Checked to find the 100% value for percentage calculations
@
Designate the 100% value (default: 100)
Range: –2147483648 to 2147483647
0%
*2
(Specify 0% value using either of Table Entry or Value.)
Table Entry
Numeral memory table number checked to find the 0% value
for percentage calculations
@
Designate the number of the numeral memory table that
stores the 0% value.
Range: 0 to 1999
Value
Checked to find the 0% value for percentage calculations
@
Designate the 0% value (default: 0)
Range: –2147483648 to 2147483647
–100%
*2
(Specify –100% value using either of Table Entry or Value.)
Table Entry
Numeral memory table number checked to find the –100%
value for percentage calculations
@
Designate the number of the numeral memory table that
stores the –100% value.
Range: 0 to 1999
Value
Checked to find the –100% value for percentage calculations
@
Designate the –100% value (default: –100)
Range: –2147483648 to 2147483647
*1: When making the setting, ensure that the total of the Start Table Entry and No. of
Points does not exceed the maximum table entry.
*2: The –100% value, 0% value, and 100% value must comply with the following
relationship:
–100% value < 0% value < 100% value
electronic components distributor
Summary of Contents for NT21 Series
Page 3: ...iv Downloaded from Elcodis com electronic components distributor...
Page 5: ...vi Downloaded from Elcodis com electronic components distributor...
Page 463: ...Downloaded from Elcodis com electronic components distributor...
Page 465: ...Downloaded from Elcodis com electronic components distributor...