Section
Using the Alarm List/History Function
338
•
String Table Entry:
Table No. (0 to 1999) of the character string memory table to be displayed as a
message
•
Image/Library Code:
Image/library code displayed together with a message
•
0000
H
:
No display
•
0001
H
to 0FFF
H
:
Image
•
1000
H
to 3FFF
H
:
Library
•
Screen No.
Screen No. (0001 to 3999) of the screen to be displayed when the message
is pressed twice.
This setting is valid only when switching the screen.
Alarm List/History
Register an alarm list/history to a screen in the manner described below (for in-
formation not indicated below, set as needed.).
•
Alarm list
•
Start bit table entry:
Table No. of the first bit memory table among the bit memory tables where
the bits in the host to be monitored are registered.
•
No. of bits referenced:
The number of the bit memory tables where the bits in the host to be moni-
tored are registered.
•
Alarm history
•
Type: Order of frequency or order of occurrence
To display the alarm history in the order of occurrence, set the display order
(From Old Data/From New Data) of the record data using the Hist. Disp.
Method memory switch of the PT.
Reference:
The image and library codes are different when NT30/620 compatible mode is
being used.
Operation
1, 2, 3...
1. Initialize the recorded alarm history record data as needed.
To initialize the alarm history record data using System Menu operation, se-
lect Alarm History on the MEMORY INIT. MENU screen.
To initialize the alarm history record data by operation at the PT status con-
trol area, change the status of bit 1 in the 4th word (word n + 3) from the be-
ginning of the PT status control area to 1 (ON).
After initializing the alarm history record data by operation at the PT status
control area, return the status of bit 1 to 0 (OFF).
2. Display the screen where the alarm list/history is registered.
In the case of an alarm history, the recorded data is displayed on the screen.
In the case of an alarm list, the content of the set character string memory
table is displayed as a message if the status of the bit in the host to be moni-
tored changes to 1 (ON).
electronic components distributor
Summary of Contents for NT21 Series
Page 3: ...iv Downloaded from Elcodis com electronic components distributor...
Page 5: ...vi Downloaded from Elcodis com electronic components distributor...
Page 463: ...Downloaded from Elcodis com electronic components distributor...
Page 465: ...Downloaded from Elcodis com electronic components distributor...