7. TROUBLESHOOTING PROCEDURE
Panel display
(The mark indicates no
message in the upper row.)
ON
LINE
lamp
Inspec-
tion
lamp
Details
Remedial
measure
Belt Reflex Error
varies
On
Belt reflectance check error
Because the PU firmware does not
notice this status to the CU firmware
in the Shipping Mode even when the
PU firmware has detected this status,
this error does not occur in the user
environment.
—
Density Shutter
Error2
varies varies Density correction shutter error 2
Because the PU firmware does not
notice this status to the CU firmware
in the Shipping Mode even when the
PU firmware has detected this status,
this error does not occur in the user
environment.
—
Density Shutter
Error1
varies varies Density correction shutter error 1
Because the PU firmware does not
notice this status to the CU firmware
in the Shipping Mode even when the
PU firmware has detected this status,
this error does not occur in the user
environment.
—
Density Color
Calibration Error
varies varies Density correction color calibration
error
Because the PU firmware does not
notice this status to the CU firmware
in the Shipping Mode even when the
PU firmware has detected this status,
this error does not occur in the user
environment.
—
Density Color Sensor
Error
varies varies Density correction color sensor error
Because the PU firmware does not
notice this status to the CU firmware
in the Shipping Mode even when the
PU firmware has detected this status,
this error does not occur in the user
environment.
—
Panel display
(The mark indicates no
message in the upper row.)
ON
LINE
lamp
Inspec-
tion
lamp
Details
Remedial
measure
Density Black
Calibration Error
varies varies Density correction black calibration
error.
Because the PU firmware does not
notice this status to the CU firmware
in the Shipping Mode even when the
PU firmware has detected this status,
this error does not occur in the user
environment.
—
Density Black Sensor
Error
varies varies Density correction black sensor error.
Because the PU firmware does not
notice this status to the CU firmware
in the Shipping Mode even when the
PU firmware has detected this status,
this error does not occur in the user
environment.
—
%COLOR% Image
Drum Smear Error
varies varies Density correction ID ERROR 2.
This error occurs when abnormal
density due to the LED head focus
error is detected. (Extremely stained
LED head)
Because the PU firmware does not
notice this status to the CU firmware
in the Shipping Mode even when the
PU firmware has detected this status,
this error does not occur in the user
environment.
%COLOR%
yellow
Magenta
Cyan
Black
—