(00235)
3-38
3.2.15 Synchronized Timing Selection (SYNC TIME)
While in the STOP mode, the synchronize timing can be selected from the SYS MENU on the J-PAD3.
The MEMRECAM GX-3 can be synchronized with the time on the timer of the device where connected.
Camera
Synchronized
Time
Synchronized timing with the internal camera timer. Select if the MEMRECAM GX-3 is used
alone or if there is no need for precise synchronization. If a control PC is connected,
synchronization with the PC time is possible.
GX-HUB
Synchronized
Time
Synchronized timing with the internal GX-HUB timer. Select if there are multiple camera
connections using the GX-HUB. If a control PC is connected, synchronization with the PC time is
possible.
IRIG
Synchronized
Time
Synchronized timing with the IRIG-B time code. Select from the following.
・
If the MEMRECAM GX-3 used alone and the IRIG-B time code is input from the J3 cable
IRIG-B connector
・
If multiple cameras are connected using the GX-HUB and the IRIG-B time code is input to the
GX-HUB
・
If multiple cameras are connected to the MEMRECAM GX-3 and another camera from the
MEMRECAM series, and the GX-HUB is connected to the M-HUB, and the IRIG-B time code
is input to the M-HUB
3.2.15.1 Setting Method
1) While in the STOP mode , press MENU
to display the
TOPTOP MENU.
2) Use the arrows
to select “SYS MENU” from the TOP
MENU , and then press SET
to display SYS MENU.
3) Use the arrows
to select “SYNCTIME” from the SYS
MENU
(
Figure 3-45
)。
4) Use the arrows
to select the synchronized time.
ASYNC
Synchronized with the internal timer of the camera
GX-HUB
Synchronized with the internal timer of the GX-HUB
IRIG
Synchronized with the IRIG-B time code
Refer to the
【
GX-HUB User's Manual
】
for multiple connections using the GX-HUB.
3.2.15.2 IRIG Synchronized Time
Confirm whether or not the time is synchronized with the IRIG-B time code on the VIEW screen.
1) While in the STOP mode, press VIEW/ARM
on the J-PAD3
to switch to the VIEW mode.
2) If
"
Ⅰ
" is displayed in green in the frame counter superimposed
over the image, it is synchronized to the standard timing of the
IRIG-B time code.
3) If
"
Ⅰ
" is displayed in red, the IRIG-B time code is not input
properly.
Figure3-45 SYNC SEL
Summary of Contents for MC-529
Page 2: ... 00235 ...
Page 4: ... 00235 2 Blank page ...
Page 10: ... 00235 8 Blank page ...
Page 16: ... 00235 vi Blank page ...
Page 17: ... 00235 1 1 1 Overview ...
Page 28: ... 00235 1 12 Blank page ...
Page 29: ... 00235 2 1 2 Basic Operations ...
Page 42: ... 00235 2 14 Fig 2 23 Dial key operation of J PAD3 ...
Page 52: ... 00235 2 24 Blank page ...
Page 53: ... 00235 3 1 3 Recording and Playback Settings ...
Page 112: ... 00235 3 60 Blank page ...
Page 113: ... 00235 4 1 4 Save Settings ...
Page 118: ... 00235 4 6 Blank page ...
Page 119: ... 00235 5 1 5 System Settings ...
Page 137: ... 00235 6 1 6 Troubleshooting ...
Page 141: ... 00235 7 1 7 Specifications ...
Page 162: ... 00235 7 22 7 11 Exterior Diagram 7 11 1 GX 3 Camera Main Unit ...
Page 171: ... 00235 8 1 8 Options ...
Page 175: ... 00235 8 5 8 2 Exterior Diagram 8 2 1 AC Adapter 約3000 255 127 7 2 3 ...
Page 176: ... 00235 8 6 8 2 2 J PAD3 18 65 140 2900 ...
Page 178: ... 00235 8 8 8 2 5 5 7 inch LCD Viewfinder ...
Page 180: ... 00235 8 10 8 2 7 C mount Adapter ...