![Mitsubishi Electric MELSERVO MR-J4-A-RJ Series Instruction Manual Download Page 93](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j4-a-rj-series/melservo-mr-j4-a-rj-series_instruction-manual_238320093.webp)
4. HOW TO USE THE POINT TABLE
4 - 6
No. Start-up
sequence
Fault
Investigation Possible
cause
Reference
3
Perform a home
position return.
Servo motor does not
rotate.
Call the external I/O signal
display and check the on/off
status of the input signal. (Refer
to section 3.7.)
LSP, LSN, and ST1 are off.
Section
3.7
Check [Pr. PA11 Forward
rotation torque limit] and [Pr.
PA12 Reverse rotation torque
limit].
Torque limit level is too low as
compared to the load torque.
Section
7.2.1
When TLA (Analog torque limit)
is usable, check the input voltage
on the status display.
Torque limit level is too low as
compared to the load torque.
Section
3.2
The home position
return is not completed.
Call the external I/O signal
display and check the on/off
status of input signal DOG.
(Refer to section 3.7.)
The proximity dog is set
incorrectly.
Section
3.7
4
Switch on ST1
(Forward rotation
start) or ST2
(Reverse rotation
start).
Servo motor does not
rotate.
Call the external I/O signal
display (section 3.7) and check
the on/off status of the input
signal.
LSP, LSN, ST1, and ST2 are off.
Section
3.7
Check [Pr. PA11 Forward rotation
torque limit] and [Pr. PA12
Reverse rotation torque limit].
Torque limit level is too low as
compared to the load torque.
Section
7.2.1
When TLA (Analog torque limit) is
usable, check the input voltage on
the status display.
Torque limit level is too low as
compared to the load torque.
Section
3.2
5 Gain
adjustment Rotation ripples (speed
fluctuations) are large
at low speed.
Make gain adjustment in the
following procedure.
1. Increase the auto tuning
response level.
2. Repeat acceleration and
deceleration several times to
complete auto tuning.
Gain adjustment fault
MR-J4-
_A_
Chapter
6
Large load inertia
moment causes the
servo motor shaft to
oscillate side to side.
If the servo motor may be driven
with safety, repeat acceleration
and deceleration several times to
complete auto tuning.
Gain adjustment fault
MR-J4-
_A_
Chapter
6
Note. Only a list of alarms and warnings is listed in chapter 8. Refer to "MELSERVO-J4 Servo Amplifier Instruction Manual
(Troubleshooting)" for details of alarms and warnings.
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...