![Mitsubishi Electric MELSERVO MR-J4-A-RJ Series Instruction Manual Download Page 189](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j4-a-rj-series/melservo-mr-j4-a-rj-series_instruction-manual_238320189.webp)
5. HOW TO USE THE PROGRAM
5 - 30
5.2.3 Basic settings of signals and parameters
Create a program with MR Configurator2 in advance. (Refer to section 5.2.2.)
(1) Parameter
(a) Setting range of the position data
The following shows the setting of [Pr. PA01].
Command method
Travel command
[Pr. PT01]
Position data input range
Positioning
command method
Position data unit
Absolute value
command method
Absolute value travel
command
("MOV", "MOVA")
_ _ _0
_ 0_ _
[mm]
-999999 to 999999 [×10
STM
μ
m]
_ 1_ _
[inch]
-999999 to 999999 [×10
(STM-4)
inch]
_ 2_ _
[degree] -360.000 to 360.000
_ 3_ _
[pulse]
-999999 to 999999
Incremental value
travel command
("MOVI", "MOVIA")
_ 0_ _
[mm]
-999999 to 999999 [×10
STM
μ
m]
_ 1_ _
[inch]
-999999 to 999999 [×10
(STM-4)
inch]
_ 2_ _
[degree] -999.999 to 999.999
_ 3_ _
[pulse]
-999999 to 999999
Incremental value
command method
Incremental value
travel command
("MOVI", "MOVIA")
_ _ _1
_ 0_ _
[mm]
-999999 to 999999 [×10
STM
μ
m]
_ 1_ _
[inch]
-999999 to 999999 [×10
(STM-4)
inch]
_ 2_ _
[degree] -999.999 to 999.999
_ 3_ _
[pulse]
-999999 to 999999
(b) Positioning command method selection ([Pr. PT01])
Make sure that the absolute value command method is selected as shown below.
[Pr. PT01]
0
Absolute value command method (initial value)
(c) Rotation direction selection/travel direction selection ([Pr. PA14])
Select the servo motor rotation direction when ST1 (Forward rotation start) is switched on.
[Pr. PA14] setting
Servo motor rotation direction
when ST1 (Forward rotation
start) is switched on
0
(Initial value)
CCW rotation with + position data
CW rotation with - position data
1
CW rotation with + position data
CCW rotation with - position data
Forward rotation
(CCW)
Reverse rotation
(CW)
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...