10. COMMUNICATION FUNCTION
10 - 23
10.2.5 Output signal pin on/off (output signal (DO) forced output)
In the test operation mode, the output signal pins can be turned on/off regardless of the servo status. Using
command [9] [0], disable the external input signals in advance.
(1) Selecting the output signal (DO) forced output of the test operation mode
Transmit c [8] [B] + data No. [0] [0] + data "0004" to select the output signal (DO) forced
output.
0
0 4
Selection of test operation mode
4: Output signal (DO) forced output
0
(2) External output signal on/off
Transmit the following communication commands.
Command
Data No.
Setting data
[9] [2]
[A] [0]
See below.
b31
b1b0
1: On
0: Off
Command of each bit is transmitted to the master station as hexadecimal data.
Bit
CN1 connector pin
Bit
CN1 connector pin
Bit
CN1 connector pin
Bit
CN1 connector pin
0 49
8 14
16
24
1 24
9
17
25
2
23
10
18
26
3
25
11
19
27
4
22
12
20
28
5
48
13
21
29
6
33
14
22
30
7
13
15
23
31
(3) Output signal (DO) forced output
To stop the output signal (DO) forced output, transmit command [8] [B] + data No. [0] [0] + data. Before
switching from the test operation mode to the normal operation mode, turn off the servo amplifier once.
Command Data
No.
Transmission
data
Selection of test operation mode
[8] [B]
[0] [0]
0000
Test operation mode canceled
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...