3. DISPLAY AND OPERATION SECTIONS
3 - 13
Name Display Description
Software version - Lower
Indicates the version of the software.
Software version - Upper
Indicates the system number of the software.
Automatic VC offset (Note)
If offset voltages in the analog circuits inside and
outside the servo amplifier cause the servo motor
setting speed not to be the designated value at VC
(Analog override) of 0 V, a zero-adjustment of offset
voltages will be automatically performed. When
using the VC automatic offset, enable it in the
following procedures. When it is enabled, [Pr. PC37]
value changes to the automatically adjusted offset
voltage.
1) Press the "SET" once.
2) Set the number in the first digit to 1 with
"UP"/"DOWN".
3) Press the "SET".
This function cannot be used if the input voltage of
VC is - 0.4 V or less, or + 0.4 V or more.
Servo motor series ID
Push the "SET" button to show the series ID of the
servo motor currently connected.
For indication details, refer to appendix 1 of "Servo
Motor Instruction Manual (Vol. 3)".
Servo motor type ID
Push the "SET" button to show the type ID of the
servo motor currently connected.
For indication details, refer to appendix 1 of "Servo
Motor Instruction Manual (Vol. 3)".
Servo motor encoder ID
Push the "SET" button to show the encoder ID of
the servo motor currently connected.
For indication details, refer to appendix 1 of "Servo
Motor Instruction Manual (Vol. 3)".
For manufacturer adjustment
This is for manufacturer adjustment.
For manufacturer adjustment
This is for manufacturer adjustment.
Teaching function
Refer to section 3.10.
After an operation travels to a target position
(MEND (Travel completion) is turned on) with a JOG
operation or manual pulse generator operation,
pushing the "SET" button of the operation part or
turning on TCH (Teach) will import position data.
This function is available only in the point table
method. For other control mode, the display remains
the same.
Note. Even if VC automatic offset is performed and 0 V is inputted, the speed may not completely be the set value.
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...