![Mitsubishi Electric MELSERVO MR-J4-A-RJ Series Instruction Manual Download Page 71](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j4-a-rj-series/melservo-mr-j4-a-rj-series_instruction-manual_238320071.webp)
3. DISPLAY AND OPERATION SECTIONS
3 - 10
(3) Changing the status display screen
The status display item of the servo amplifier display shown at power-on can be changed by changing
[Pr. PC36] settings. The item displayed in the initial status changes with the control mode as follows.
Control mode
Status display
Position
Cumulative feedback pulses
Position/speed
Cumulative feedback pulses/servo motor speed
Speed
Servo motor speed
Speed/torque
Servo motor speed/analog torque command voltage
Torque
Analog torque command voltage
Torque/position
Analog torque command voltage/cumulative feedback
pulses
Positioning (point table method/program
method)
Current position
Positioning (indexer method)
Cumulative feedback pulses