7. PARAMETERS
7 - 61
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control mode
CP CL PS
PD42
*DIA4
Input signal
automatic on
selection 4
_ x _ _
(HEX)
_ _ _ x (BIN): DI0 (point table No/Program No./next station No. selection 1)
0h
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ x _ (BIN): DI1 (point table No/program No./next station No. selection 2)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): DI2 (point table No/program No./next station No. selection 3)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): DI3 (point table No/program No./next station No. selection 4)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _
(HEX)
_ _ _ x (BIN): DI4 (point table No/Program No./next station No. selection 5)
0h
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ x _ (BIN): DI5 (point table No/program No./next station No. selection 6)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): DI6 (point table No/program No./next station No. selection 7)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): DI7 (point table No/program No./next station No. selection 8)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
Convert the setting value into hexadecimal as follows.
0
Initial value
BIN HEX
Signal name
0
0
0
0
0
DI2 (Point table No/Program No./Next station No. selection 3)
DI0 (Point table No/Program No./Next station No. selection 1)
DI1 (Point table No/Program No./Next station No. selection 2)
DI3 (Point table No/Program No./Next station No. selection 4)
0
Initial value
BIN HEX
Signal name
0
0
0
0
RTCDP (Second acceleration/deceleration gain selection)
RT (Second acceleration/deceleration selection)
0
Initial value
BIN HEX
Signal name
0
0
0
0
DI4 (Point table No/Program No./Next station No. selection 5)
DI5 (Point table No/Program No./Next station No. selection 6)
DI6 (Point table No/Program No./Next station No. selection 7)
DI7 (Point table No/Program No./Next station No. selection 8)
BIN 0: Use for an external input signal.
BIN 1: Automatic on
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...