5. HOW TO USE THE PROGRAM
5 - 67
(4) Pasting text (d)
Click the "Paste" button to paste the copied text on the clipboard to a specified place of the program edit
area.
(5) Ending window for program (e)
Click the "OK" button to execute the edit check. When the edit check completes with no error, the edit
will finish and the window for program edit will be closed. When the edit check detects an error in the
program, it will be displayed.
(6) Canceling window for program edit (f)
Click the "Cancel" button to close the window for program edit without saving the program currently
being edited.
(7) Displaying error (g)
When the edit check of (5) detects an error in the program, the row No. and content of the error will be
displayed. Click the error content, the cursor will move to the row of the corresponding program.
5.8.3 Indirect addressing window
Set general purpose registers (D1 to D4 and R1 to R4) in this screen.
(b)
(c)
(a)
(1) Register edit field (a)
Set general purpose register values of D1 to D4 and R1 to R4.
(2) Register reference field (b)
The last register value read from the amplifier is displayed.
(3) ROM writing button (c)
You can write register values (D1 to D4 and R1 to R4) stored in the servo amplifier to the servo
amplifier.
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...