7. PARAMETERS
7 - 72
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control mode
CP CL PS
PT19
*LPPL
Position
range output
a
(third least
significant
digit)
Set an address increasing side of the position range output address.
Upper and lower are a set. Set a range which POT (Position range) turns on with
[Pr. PT19] to [Pr. PT22].
Setting address:
Upper
3 digits
Lower
3 digits
[Pr. PT19]
[Pr. PT20]
Set a same sign for [Pr. PT19] and [Pr. PT20]. Setting a different sign will trigger
[AL. 37 Parameter error].
When changing a setting, always set the third least significant digit before setting the
third most significant digit.
The unit will be changed to 10
STM
[
μ
m], 10
-(STM-4)
[inch], 10
-3
[degree], or [pulse] with the
setting of [Pr. PT01].
Setting range: -999999 to 999999
0
Refer to
Function
column
for unit.
PT20
*LPPH
Position
range output
a
(third most
significant
digit)
PT21
*LNPL
Position
range output
address -
(third least
significant
digit)
Set an address decreasing side of the position range output address.
Upper and lower are a set. Set a range which POT (Position range) turns on with
[Pr. PT19] to [Pr. PT22].
Setting address:
Upper
3 digits
Lower
3 digits
[Pr. PT21]
[Pr. PT22]
Set a same sign for [Pr. PT21] and [Pr. PT22]. Setting a different sign will trigger
[AL. 37 Parameter error].
When changing a setting, always set the third least significant digit before setting the
third most significant digit.
The unit will be changed to 10
STM
[
μ
m], 10
-(STM-4)
[inch], 10
-3
[degree], or [pulse] with the
setting of [Pr. PT01].
Setting range: -999999 to 999999
0
Refer to
Function
column
for unit.
PT22
*LNPH
Position
range output
address -
(third most
significant
digit)
PT23
OUT1
OUT1 output
setting time
Set an output time for when OUT1 (Program output 1) is turned on with the OUTON
command.
Setting "0" will keep on-state. To turn it off, use the OUTOF command.
Setting range: 0 to 20000
0
[ms]
PT24
OUT2
OUT2 output
setting time
Set an output time for when OUT2 (Program output 2) is turned on with the OUTON
command.
Setting "0" will keep on-state. To turn it off, use the OUTOF command.
Setting range: 0 to 20000
0
[ms]
PT25
OUT3
OUT3 output
setting time
Set an output time for when OUT3 (Program output 3) is turned on with the OUTON
command.
Setting "0" will keep on-state. To turn it off, use the OUTOF command.
Setting range: 0 to 20000
0
[ms]
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...