![Mitsubishi Electric MELSERVO MR-J4-A-RJ Series Instruction Manual Download Page 313](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j4-a-rj-series/melservo-mr-j4-a-rj-series_instruction-manual_238320313.webp)
7. PARAMETERS
7 - 56
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control mode
CP CL PS
PD23
*DO1
Output device
selection 1
_ _ x x Device selection
Any output device can be assigned to the CN1-22 pin.
Refer to table 7.10 for settings.
04h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
Table 7.10 Selectable output devices
Setting
value
Output device (Note)
CP
CL
PS
00
Always off
Always off
Always off
02
RD
RD
RD
03
ALM
ALM
ALM
04
INP
INP
INP
05
MBR
MBR
MBR
06
DB
DB
DB
07
TLC
TLC
TLC
08
WNG
WNG
WNG
09
BWNG
BWNG
BWNG
0A
SA
SA
Always
off
0B
Always off
Always off
Always off
0C
ZSP
ZSP
ZSP
0D
MTTR
MTTR
MTTR
0F
CDPS
CDPS
CDPS
10
CLDS
CLDS
CLDS
11
ABSV
ABSV
ABSV
23
CPO
CPO
CPO
24
ZP
ZP
ZP
25
POT
POT
Always
off
26
PUS
PUS
Always
off
27
MEND
MEND
MEND
2C
PED
PED
2D
SOUT
2E
OUT1
2F
OUT2
30
OUT3
31 ALMWNG ALMWNG ALMWNG
32
BW9F
BW9F
BW9F
33
MSDH
MSDH
34
MSDL
MSDL
38
PT0
PS0
39
PT1
PS1
3A
PT2
PS2
3B
PT3
PS3
3C
PT4
PS4
3D
PT5
PS5
3E
PT6
PS6
3F
PT7
PS7
Note. CP: Positioning mode (point table method)
CL: Positioning mode (program method)
PS: Positioning mode (indexer method)
The diagonal lines indicate manufacturer settings. Never change the setting.
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...