![Mitsubishi Electric MELSERVO MR-J4-A-RJ Series Instruction Manual Download Page 104](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j4-a-rj-series/melservo-mr-j4-a-rj-series_instruction-manual_238320104.webp)
4. HOW TO USE THE POINT TABLE
4 - 17
(3) Automatic operation timing chart
(a) Automatic individual positioning operation
1) Absolute value command method ([Pr. PT01] = _ _ _ 0)
While the servo motor is stopped under servo-on state, switching on ST1 (Forward rotation start)
starts the automatic positioning operation.
The following shows a timing chart.
MD0
(Operation mode selection 1)
ON
OFF
ON
OFF
SON (Servo-on)
ON
OFF
ST1
(Forward rotation start)
ST2
(Reverse rotation start)
ON
OFF
Point table No.
Forward rotation
0 r/min
Reverse rotation
Servo motor
speed
ON
OFF
INP (In-position)
ON
OFF
CPO (Rough match)
MEND
(Travel completion)
ON
OFF
PT0 (Point table No.
output 1) to PI7 (Point
table No. output 8)
M code output
ON
OFF
RD (Ready)
ALM (Malfunction)
ON
OFF
(Note)
3 ms or
longer
3 ms or
longer
Point table
No. 1
Point table
No. 2
1
2
1
2
M code of point table No. 1
3 ms or shorter
5 ms or
longer
5 ms or
longer
Note. The detection of external input signals is delayed by the set time in the input filter setting of [Pr. PD29].
Considering the output signal sequence from the controller and signal variations due to hardware, configure a
sequence that changes the point table selection earlier.
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...