![Mitsubishi Electric MELSERVO MR-J4-A-RJ Series Instruction Manual Download Page 222](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j4-a-rj-series/melservo-mr-j4-a-rj-series_instruction-manual_238320222.webp)
5. HOW TO USE THE PROGRAM
5 - 63
5.6 Incremental value command method
When using this servo amplifier under the incremental value command method, you must change the setting
of [Pr. PT01].
As position data, set the travel distance from the current address to the target address. The incremental
value command method enables infinitely long constant rate of feeding.
Setting range: -999999 to 999999 [×10
STM
μ
m] (STM = Feed length multiplication [Pr. PT03])
Position data = |Target address - Current address|
Current address
Target address
This section indicates contents different from the absolute value command method (factory setting) when
this servo amplifier is used under the incremental value command method.
(1) Parameter setting
Set [Pr. PT01] to select the incremental value command method as shown below.
[Pr. PT01]
Incremental value command method
1
(2) Command
The command contents of "MOV" and "MOVA" are changed as follows. There are no changes in other
command. Thus, the command contents are the same between "MOV" and "MOVI", and between
"MOVA" and "MOVIA".
Command Name
Setting Setting
range Unit
Indirect
specifica
tion
Description
MOV
Incremental
value travel
command
MOV (setting
value)
-999999 to
999999
×10
STM
μ
m
The servo motor rotates using the set value as the incremental
value.
The same as "MOVI" command
MOVA
Incremental
value
continuous
travel command
MOVA
(setting value)
-999999 to
999999
×10
STM
μ
m
The servo motor rotates continuously as the set incremental
value.
Make sure to describe this command after the "MOV"
command. If this command is described after other command,
an error will occur.
The same as "MOVIA" command
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...