4. HOW TO USE THE POINT TABLE
4 - 31
Example 2. Operations when "11" is set to the sub function of point table No. 3
Point table
No.
Position data
[10
STM
μ
m]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms] Sub
function
M
code
1 5.00
3000
100
150
100 3 05
2 10.00
2000 150 200
200 1 10
3 5.00 1000 300 100 150
11
15
Operation sequence
1) Starting with point table No. 2
2) Executing point table No. 3
3) Executing point table No.1 when "11" is set to the sub function of point table No. 3
4) Repeating the above execution in the sequence of 1) to 2) to 3) to 1) to 2) to 3)
Servo motor speed
Forward rotation
0 r/min
Reverse rotation
Position address
Point table No. to select
ST1 (Forward rotation start)
ON
OFF
PT0 (Point table No. output 1)
to PI7 (Point table No. output 8)
(Note)
M code output (Note)
Point table No. 2
Speed
(2000)
Speed (1000)
Point table No. 3
5.00
1)
1)
2)
3)
0
10.00
15.00
2
Speed
(2000)
Speed
(3000)
Point table No. 1
5.00
Point table No. 2
Note. PT0 to PT7 and M code are not outputted in automatic continuous operation.
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...