6. HOW TO USE INDEXER
6 - 11
The following timing chart shows that an operation is performed at a stop of the station No. 0 when
servo-on.
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
Power supply
ON
OFF
ON
OFF
ON
OFF
ALM (Malfunction)
MEND (Travel completion)
PS0 (Station output 1) to
PS7 (Station output 8)
DI0 (Next station No. selection 1) to
DI7 (Next station No. selection 8)
Servo motor speed
Forward rotation
0 r/min
Reverse rotation
ON
OFF
ST1 (Forward rotation start)
ON
OFF
SIG
(External limit/Rotation direction
decision/Automatic speed selection)
ON
OFF
RT
(Second acceleration/
deceleration selection)
ON
OFF
MD0 (Operation mode selection 1)
ON
OFF
MD1 (Operation mode selection 2)
Torque limit
5 ms or
longer
[Pr. PC30]
setting time
Torque limit value of
[Pr. PA11] and [Pr. PA12]
Torque limit value of
[Pr. PA11] and [Pr. PA12]
Torque limit value
of [Pr. PC35]
Torque limit value
of [Pr. PC35]
Torque limit value
of [Pr. PC35]
Torque limit value of
[Pr. PA11] and [Pr. PA12]
Station position
No. 3
Automatic
operation
speed 2
5 ms or
longer
All off (Note 4)
All off (Note 4)
All off (Note 4)
Station
output 1
Number of stations: 8
5 ms or
longer
5 ms or
longer
[Pr. PC31]
setting time
[Pr. PT39] setting time (Note 3)
Station position
No. 1
Automatic
operation
speed 1
Next station No. selection 3
[Pr. PC02]
setting time
[Pr. PC01]
setting time
Station position
No. 1
Next station No. selection 1
Next station No. selection 1
Station output 1
Station output 3
Ignored (Note 2)
Ignored (Note 1)
Automatic operation
speed 1
Note 1. When the rest of command travel distance is other than "0", ST1 (Forward rotation start) will not be accepted. Refer to section
6.4.5 (1).
2. RT (Second acceleration/deceleration selection) will not be accepted during operation. Selection of the servo motor speed and
acceleration/deceleration time constants will be enabled by on-edge of ST1 (Forward rotation start). However, when the rest of
command travel distance is other than "0", turning on ST1 (Forward rotation start) will not be enabled.
3. Counting will start when the rest of command travel distance becomes "0".
4. When MEND (Travel completion) is off, the station position outputs will be "0" (all off).
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...