![Mitsubishi Electric MELSERVO MR-J4-A-RJ Series Instruction Manual Download Page 407](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j4-a-rj-series/melservo-mr-j4-a-rj-series_instruction-manual_238320407.webp)
11. PARAMETER UNIT
11 - 18
The following shows the operation condition settings and the operation methods.
Speed
Displays the servo motor speed of the positioning operation.
Pulse unit
Acceleration/deceleration
time constant
Displays acceleration/deceleration time constants of the positioning operation.
When setting 1500 r/min...
When setting 2000 ms...
Travel distance
Displays the travel distance.
Operation screen
When setting the travel distance to "10000"...
When the " " + " " keys are pressed down, the motor starts to the forward rotation direction
for the set travel distance and stops.
When the " " + " " keys are pressed down, the motor starts to the reverse rotation direction
for the set travel distance and stops.
Pressing the " " will temporarily stop the motor and " " or " " key will restart.
Releasing the " " key will quickly stop the motor and remaining distance will be cleared.
Specify the travel distance unit of pulses.
0: CMD (command pulse unit)
1: ENC (encoder pulse unit)
Test operation mode release completed
Selecting "RESTORE" on the initial
screen of the test operation mode
without execution of the test operation
will also displays this screen.
Returns to the initial screen of the test operation mode.
Select "RESTORE".
Test operation mode release
Positioning operation
If a parameter unit cable is disconnected during positioning operation, the servo motor will stop
quickly.
(b) Status display
The status display can be monitored during positioning operation. At this time, the "FWD", "REV",
and "STOP" keys are available.
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...