4. HOW TO USE THE POINT TABLE
4 - 25
a) Positioning in a single direction
The following shows an operation example with the set values listed in the table below.
In this example, point table No. 1 and point table No. 3 are under the absolute value command
method, and point table No. 2 is under the incremental value command method.
Point table
No.
Position data
[10
STM
μ
m]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms]
(Note 1)
Sub function M
code
1 5.00
3000 100
150 0
1
05
2 3.00
2000 Disabled
Disabled
0 3
10
3 10.00
1000
Disabled
Disabled
0
1
15
4 6.00
500 Disabled
Disabled
Disabled
2 (Note 2)
20
Note 1. Always set "0".
2.
Always set "0" or "2" to the sub function of the last point table among the consecutive point tables.
0: When using the point table under the absolute value command method
2: When using the point table under the incremental value command method
Deceleration time constant
(150) of point table No. 1
Servo motor speed
Position address
Point table No. to select
ST1 (Forward rotation start)
ON
OFF
0
5.00
8.00
16.00
Speed
(3000)
Speed
(2000)
(1000)
1
Forward
rotation
0 r/min
Acceleration time constant
(100) of point table No. 1
3.00
6.00
10.00
Speed
Speed
(500)
1
PT0 (Point table No. output 1)
to PI7 (Point table No. output 8)
05
M code output
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...