6. HOW TO USE INDEXER
6 - 16
(2) Setting assignment direction of station No.
Select an assignment direction of station No. with [Pr. PA14].
CW
CCW
[Pr. PA14] setting
Servo motor rotation direction
ST1 (Forward rotation start) is on.
0
Next station No. will be assigned in CW direction in order of
1, 2, 3…
1
Next station No. will be assigned in CCW direction in order
of 1, 2, 3…
Station No.
1
2
3
4
CW direction
Station No.
1 2
3 4
CCW direction
[Pr. PA14]: 0 (initial value)
[Pr. PA14]: 1
(3) Operation
Turning on ST1 (Forward rotation start) will start rotation to a direction specified with the rotation
direction decision and turning off it will execute a positioning to the closest station position which is
possible to decelerate to a stop. However, the shaft stops based on a set time constant depending on
the setting value of deceleration time constant. The speed may not reach the specified speed.