![Mitsubishi Electric MELSERVO MR-J4-A-RJ Series Instruction Manual Download Page 359](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j4-a-rj-series/melservo-mr-j4-a-rj-series_instruction-manual_238320359.webp)
10. COMMUNICATION FUNCTION
10 - 8
(8) Point table setting data (command [4] [0], [4] [5], [5] [0], [5] [4], [5] [8], [6] [0], [6] [4])
Command Data
No.
Description
Control
mode
Frame
length
C
P
C
L
P
S
[4] [0]
[0] [0] to [F] [F] Reading position data of each point table
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
point table No.
8
[4] [5]
[0] [0] to [F] [F] Reading M code of each point table
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
point table No.
[5] [0]
[0] [0] to [F] [F] Reading speed data of each point table
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
point table No.
[5] [4]
[0] [0] to [F] [F] Reading acceleration time constant of each point table
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
point table No.
[5] [8]
[0] [0] to [F] [F] Reading deceleration time constant of each point table
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
point table No.
[6] [0]
[0] [0] to [F] [F] Reading dwell of each point table
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
point table No.
[6] [4]
[0] [0] to [F] [F] Reading sub function of each point table
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
point table No.
(9) Position data unit/Current position latch data (command [6] [C])
Command Data
No.
Description
Control
mode
Frame
length
C
P
C
L
P
S
[6] [C]
[0] [0]
Reading position data unit
_ _ _ x 0: mm, 1: inch, 2: pulse, 3: degree
_ _ x _ 0: Enabled, 1: Disabled
4
[0] [1]
Reading current position latch data
Reads data latched at rising edge of LPS signal using LPOS command in the
program operation.
12
(10) General purpose register (Rx) value (command [6] [D])
Command Data
No.
Description
Control
mode
Frame
length
C
P
C
L
P
S
[6] [D]
[0] [1]
Reading general purpose register (R1) value
8
[0] [2]
Reading general purpose register (R2) value
[0] [3]
Reading general purpose register (R3) value
[0] [4]
Reading general purpose register (R4) value
(11) General purpose register (Dx) value (command [6] [E])
Command Data
No.
Description
Control
mode
Frame
length
C
P
C
L
P
S
[6] [E]
[0] [1]
Reading general purpose register (D1) value
8
[0] [2]
Reading general purpose register (D2) value
[0] [3]
Reading general purpose register (D3) value
[0] [4]
Reading general purpose register (D4) value
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...