11. PARAMETER UNIT
11 - 19
(3) Output signal (DO) forced output
Output signals can be switched on/off forcibly independently of the servo status. This function is used for
output signal wiring check, etc. This operation must be performed in the servo off state by turning off
SON (Servo-on).
The following shows operation methods.
Test operation mode
release completed
Selecting "RESTORE" on the initial
screen of the test operation mode
without execution of the test
operation will also displays this
screen.
Returns to the initial screen
of the test operation mode.
Select "RESTORE".
Test operation mode
release
When turning on CN1-3...
Select with the " " keys
and set with the
" " key.
: Output on
: Output off
Output signal (DO) forced output
Displays output pins and their status.
(4) Single-step feed
POINT
Turn on EM2 (forced stop 2) when performing single-step feed.
Operates based on set point table No.
The following shows the operation condition settings and the operation methods.
Test operation mode
release completed
Selecting "RESTORE"
on the initial screen of
the test operation mode
without execution of the
test operation will also
displays this screen.
Returns to the initial screen
of the test operation mode.
Select "RESTORE".
Test operation mode
release
When specifying point table No. 255...
Single-step feed
The setting screen of
the point table No. is
displayed.
Pressing the " " +
" " keys will start.
After the start, pressing
the " " key with keep
pressing the " " key
will temporarily stop the
motor.
Releasing the " " key
will quickly stop the motor.
When the motor stops,
remaining distance will
be cleared.
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...