(2) Timing chart
ON
OFF
ALM (Malfunction)
ON
OFF
MEND (Travel completion)
ON
OFF
Servo motor speed
Power supply
Forward rotation
0 r/min
Reverse rotation
ON
OFF
ON
OFF
ST1 (Forward rotation start)
SIG (External limit/Rotation direction
decision/Automatic speed selection)
Home position return completion flag
ON
OFF
ON
OFF
ON
OFF
MD0 (Operation mode selection 1)
MD1 (Operation mode selection 2)
Home position
shift distance
[Pr. PC01]
setting time
[Pr. PC02]
setting time
[Pr. PT39] setting time (Note 2)
5 ms or longer
Torque limit value of [Pr. PA11] and [Pr. PA12]
Torque limit value of [Pr. PC35]
Torque limit value
of [Pr. PC35]
In-position out of range
Station output 0
Station output 0
Creep speed
Home position return speed
PS0 (Station output 1) to
PS7 (Station output 8)
Z-phase
Torque limit
Position where the station
home position shift distance
is added
5 ms or longer
Ignored (Note 1)
Note 1. When the rest of command travel distance is other than "0", turning on ST1 (Forward rotation start) will not be enabled.
2. Counting will start when the rest of command travel distance becomes "0".
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...