4. HOW TO USE THE POINT TABLE
4 - 40
c) When the software limit is deactivated
When deactivating the software limit, set the same values to the software limit - ([Pr. PT17]
and [Pr. PT18]) and the software limit + ([Pr. PT15] and [Pr. PT16]).
Control can be performed independently of the software limit setting.
3) Position range output activation/deactivation setting
a) Setting range
When the unit is "degree", the setting range of the position range output is 0 degree (lower
limit) to 359.999 degrees (upper limit).
When you set a value other than 0 degree to 359.999 degrees in [Pr. PT19] to [Pr. PT22], the
set value is converted as follows. (The value after conversion will be inside the range of 0
degree to 359.999 degrees.)
Position range output address
After conversion
360.000 degrees to 999.999 degrees
The remainder of the set value divided by
360
-0.001 degrees to -359.999 degrees
The sum of the set value and 360
-360.000 degrees to -999.999 degrees
The sum of 360 and the quotient of the set
value divided by 360
b) Effective setting of position range output
Set the position range output address - ([Pr. PT21] and [Pr. PT22]) for the start position and
the position range output a ([Pr. PT19] and [Pr. PT20]) for the target position.
The movable range is the section from - to + in the CCW direction.
90
0
315
Section A
CCW
90
0
315
CCW
Section B
Set the movable range of section A as follows.
Position range output address - ··· 315.000 degrees
Position range output a ··· 90.000 degrees
Set the movable range of section B as follows.
Position range output address - ··· 90.000 degrees
Position range output a ··· 315.000 degrees
Summary of Contents for MELSERVO MR-J4-A-RJ Series
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 8 MEMO ...
Page 61: ...2 SIGNALS AND WIRING 2 38 MEMO ...
Page 227: ...5 HOW TO USE THE PROGRAM 5 68 MEMO ...
Page 257: ...6 HOW TO USE INDEXER 6 30 MEMO ...
Page 339: ...7 PARAMETERS 7 82 MEMO ...
Page 351: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO ...
Page 411: ...11 PARAMETER UNIT 11 22 MEMO ...
Page 415: ...SH NA 030143 A ...