2. INSTALLATION
2 - 5
2.6 Cable
The power supply and encoder cables routed from the servo motor should be fixed to the servo motor to
keep them unmovable. Otherwise, the cable may disconnect. In addition, do not modify the connectors,
terminals and others at the ends of the cables.
2.7 Servo motor with oil seal
For the servo motor with oil seal, the oil seal prevents the entry of oil into the servo motor. Make sure to
install it according in this section.
The functions have no problem even if the servo motor with oil seal may sound during operation.
(1) Pressure and oil level
Install the servo motor horizontally, and set the oil level in the gear box to be lower than the oil seal lip
always. If the oil level is higher than the oil seal lip, the oil enter the servo motor and may cause a
malfunction. Refer to the chapter of the servo motor series for the oil level.
Gear
Shaft
Servo motor
Oil seal
Height above oil level h
Lip
High pressure against the oil seal causes the abrasion and makes the life be short. Keep constant
internal pressure by equipping a ventilator to the gear box.
(2) Temperature
High temperature against the oil seal lip makes the life be short. Avoid exposing the oil seal lip to high
temperature oil since applicable temperature of the material is up to 100 °C and temperature of the oil
seal lip rises within 10 °C to 15 °C at maximum rotation.
2.8 Inspection items
WARNING
Before starting maintenance and/or inspection, turn off the power and wait for 15
minutes or more (20 minutes or more for converter unit and drive unit) until the
charge lamp turns off. Then, confirm that the voltage between P+ and N- (L+ and
L- for converter unit and drive unit) is safe with a voltage tester and others.
Otherwise, an electric shock may occur. In addition, when confirming whether the
charge lamp is off or not, always confirm it from the front of the servo amplifier
(converter unit).
To avoid an electric shock, only qualified personnel should attempt inspections.
For repair and parts replacement, contact your local sales office.
CAUTION
Do not perform insulation resistance test on the servo motor. Otherwise, it may
cause a malfunction.
Do not disassemble and/or repair the equipment on customer side.
Summary of Contents for HG-AK
Page 9: ...A 8 MEMO ...
Page 103: ...5 WIRING OPTION 5 34 MEMO ...
Page 163: ...6 HG MR SERIES HG KR SERIES 6 60 MEMO ...
Page 321: ...9 HG RR SERIES 9 12 MEMO ...
Page 333: ...10 HG UR SERIES 10 12 MEMO ...
Page 347: ...11 HG AK SERIES 11 14 MEMO ...