11. HG-AK SERIES
11 - 3
5. The following figure shows the vibration directions. The value is the one at the part that indicates the maximum value (normally
the opposite to load-side bracket). When the servo motor stops, fretting is likely to occur at the bearing. Therefore, suppress
the vibration to about half of the permissible value.
Y
X
Servo motor
Vibration
Speed [r/min]
0 1000 2000 3000 4000 5000 6000 7000
10
100
1000
V
ib
rat
ion ampl
itud
e
(both amplitudes) [
μ
m]
6. V10 indicates that the amplitude of a single servo motor is 10
μ
m or less. The following figure shows the servo motor mounting
position for measurement and the measuring position.
Servo motor
Top
Bottom
Measuring position
7. The following shows permissible load for the shaft. Do not subject the shaft to load greater than the value in the specifications
list. The value assumes that the load is applied independently.
L
Radial load
Thrust load
L: Distance from flange mounting surface to load center
Summary of Contents for HG-AK
Page 9: ...A 8 MEMO ...
Page 103: ...5 WIRING OPTION 5 34 MEMO ...
Page 163: ...6 HG MR SERIES HG KR SERIES 6 60 MEMO ...
Page 321: ...9 HG RR SERIES 9 12 MEMO ...
Page 333: ...10 HG UR SERIES 10 12 MEMO ...
Page 347: ...11 HG AK SERIES 11 14 MEMO ...