IV
Remote Controller ]
- 47 -
HWE15070
GB
Using the Auto-Off Timer
1. This timer begins countdown when the unit starts, and shuts the unit off
when the set time has elapsed.
2. Available settings range from 30 minutes to 4 hours in 30-minute intervals.
Note:
*1 Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same
time.
*2 The Auto Off timer will not operate when any of the following conditions is
in effect.
The timer is off; the system is in error; a test run is in progress; the remote
controller is performing self-check or remote controller check; or a function
or the timer is being set. If the ON/OFF status and/or the temperature
setting is centrally controlled, their settings cannot be changed according
to the schedule that was set from the remote controller.
How to Set the Auto-Off TIMER
1. On the Normal Operation screen, make sure that “AUTO OFF” is displayed
(
).
If anything other than “AUTO OFF” is displayed, select the Auto-OFF timer
by referring to [4]-3(3) (page 49).
2. Press and hold the TIMER MENU button
for
3 seconds
, so that “Set
Up” appears on the screen (
).
(Each press toggles between “Set Up” and “Monitor”.)
3. Press the Set Time button
to set the OFF time (
).
4. Press the CIR.WATER
button
to save the setting.
Note:
The changes will not be saved unless the Mode (BACK) button
is pressed
before the CIR.WATER
button
is pressed.
5. Press the Mode (BACK) button
to complete the setting procedure and
return to the Normal Operation screen.
6. If the unit is already running, the timer will start counting down immediately.
Make sure that the remaining time is displayed on the screen and that
it is correct.
Checking the Current Auto-Off Timer Setting
1. Make sure that “AUTO OFF” is displayed (
).
2. Press and hold the TIMER MENU button
for
3 seconds
so that
“Monitor” appears (
).
• The time remaining until the unit will turn off will appear in the area
labeled .
3. To close the monitor display and return to the Normal Operation screen,
press the Mode (BACK) button
.
To Turn Off the Auto-Off Timer
• Press and hold the TIMER ON/OFF button
for
3 seconds
so that “Timer
Off” appears (
) and the timer value (
) disappears.
• Alternatively, turn off the unit itself. The timer value (
) will disappear from
the screen.
To Turn On the Auto-Off Timer
• Press and hold the TIMER ON/OFF button
for
3 seconds
. The “Timer
Off” will disappear (
), and the timer setting will appear on the display
(
).
• Alternatively, turn on the unit. The timer value will appear in the area
labeled .
PAR-W21MAA
ON/OFF
TEMP.
MENU
BACK
DAY
CHECK
TEST
MONITOR/SET
CLOCK
CLEAR
ON/OFF
INITIAL SETTING
CIR.WATER
F
F
O
R
E
T
F
A
AUTO OFF
MENU
BACK
CLOCK
ON/OFF
CHECK
TEST
CLEAR
INITIAL SETTING
CIR.WATER
F
F
O
R
E
T
F
A
AUTO OFF
1
3
2
Timer Setting
1
2
3
AFTER
TIMER
OFF
AUTO OFF
1
5
4
Timer Setting
1
4
5
6
7
˚C
˚C
F
F
O
R
E
T
F
A
AUTO OFF
6
7
7
AUTO OFF
7
6
7
7
˚C
˚C
F
F
O
R
E
T
F
A
AUTO OFF
6
7
2
9
11
4
12
12
11
4
2
4
2
12
2
9
9
0000001906.book 47 ページ 2015年11月5日 木曜日 午前11時55分
Summary of Contents for CAHV-P500YB-HPB
Page 1: ......
Page 7: ...CONTENTS HWE15070 GB ...
Page 9: ... 2 HWE15070 GB ...
Page 19: ... 12 HWE15070 GB ...
Page 37: ... 30 II Restrictions GB HWE15070 ...
Page 39: ... 32 HWE15070 GB ...
Page 48: ... 41 HWE15070 GB IV Remote Controller 1 Using the Remote Controller 43 2 Function Settings 48 ...
Page 49: ... 42 HWE15070 GB ...
Page 57: ... IV Remote Controller 50 HWE15070 GB ...
Page 58: ... 51 HWE15070 GB V Electrical Wiring Diagram 1 Electrical Wiring Diagram 53 ...
Page 59: ... 52 HWE15070 GB ...
Page 65: ... 58 V Electrical Wiring Diagram GB HWE15070 ...
Page 67: ... 60 HWE15070 GB ...
Page 71: ... VI Refrigerant Circuit 64 HWE15070 GB ...
Page 73: ... 66 HWE15070 GB ...
Page 111: ... 104 HWE15070 GB ...
Page 117: ... VIII Test Run Mode 110 HWE15070 GB ...
Page 119: ... 112 HWE15070 GB ...
Page 163: ... IX Troubleshooting 156 HWE15070 GB ...
Page 164: ... 157 HWE15070 GB X Attachments 1 R407C saturation temperature table 159 ...
Page 165: ... 158 HWE15070 GB ...
Page 167: ... X Attachments 160 HWE15070 GB ...
Page 168: ......