background image

40D

1 / ENGLISH

490001

TECHNICAL DETAILS

Figure 1: Nautic 40D

Content of the package

1 pc

Device

1 pc

Auxiliary bag

4 m

Power cord

4 m

Fuel hose with a filter

1 pc

Mounting piece

1 pc

Damper kit

Content of the auxiliary bag:

6 pcs Mounting piece screw 5 x 16

2 pcs Mounting bolt M8 x 120

2 pcs Corrugated base plate M8

1 pc

Hose clamp 20/32

4 pcs Air duct fixing clamp 60/80

1 pc

Fuse box bag

Summary of Contents for Nautic 40D

Page 1: ...1 pc Auxiliary bag 4 m Power cord 4 m Fuel hose with a filter 1 pc Mounting piece 1 pc Damper kit Content of the auxiliary bag 6 pcs Mounting piece screw 5 x 16 2 pcs Mounting bolt M8 x 120 2 pcs Corr...

Page 2: ...an intelligent Info Control Panel The heater is made entirely of stainless materials Table 1 Technical details of heater 40D TECHNICAL DETAILS l e u F l i o e c a n r u f l i o l e s e i D e g a t l...

Page 3: ...eater is equipped with 2 x 75 mm blower connections In order to secure sufficient air flow the heating air is divided to at least four gratings The upper of the 2 x 75 mm suction connections of the he...

Page 4: ...the dampening plate Figure 3 Attaching the mounting piece to the bulkhead with four 5 x 16 standard screws Figure 4 Attaching the heater to the mounting piece Figure 5 Locking the heater in place wit...

Page 5: ...t gas pipe Figure 8 The pipes of both the blow and suction duct system are attached with hose clamps The heated extracts the air from the same end where the power cord and connectors for fuel and cont...

Page 6: ...to OFF position The heater cannot be restarted until the cooling has been completed and all indicator lamps have gone out Once the indicator lamps have gone out restart the heater by switching it to H...

Page 7: ...ating and in turn the set temperature of the thermostat and the measured temperature Thermostat control Use the arrow keys to change the temperature and effect setting If you want to set a new value a...

Page 8: ...e Effect Set Current A calculated Heating effect kW Fuel Consumption l h Pump pulse password Battery voltage V Burner temp C Hours to service max 500 h Running hours h Cabin temp C Heating Ventilation...

Page 9: ...Reset the error in the main menu When using a Basic Control Panel the indicator lamps show the cause of the error Reset the error by switching off the power from the heater The cause of an error must...

Page 10: ...chlauch mit Filter 1x Halterung 1x D mpfungs Set Inhalt der Bedarfst te 6x Schrauben f r Halterung 5x16 2x Befestigungsbolzen M8x140 2x gewellte Unterlegscheibe M8 1x Schlauchverbindung 20 32 4x Befes...

Page 11: ...ses Heizger t am Besten f r Boote von 9 bis 12 m L nge Je nach Wahl besitzt das Heizger t entweder einen mit LED Anzeigen ausger steten Basis Betriebsschalter oder einen intelligenten mit Textanzeige...

Page 12: ...69 eingesetzt werden Das Heizger t besitzt 2 x 75 mm Gebl seanschl sse Zur Sicherung eines ausreichenden Luftstroms wird die Heizluft auf mindestens vier Lamellen verteilt Die beiden 75 mm Ansaugansch...

Page 13: ...g des Heizger tes mit 2 M8 F cherscheiben und M8x140 Befestigungsbolzen Abb 4 Befestigung des Heizger ts an der Halterung Abb 3 Befestigung der Halterung an der Wand mit 4 St ck 5x16 Schrauben Abb 2 Z...

Page 14: ...8 Die Rohre f r sowohl Gebl se wie Ansaugkan le werden mit Hilfe von Schlauchklemmen befestigt Das Heizger t saugt die Luft von dem Ende an wo sich Stromkabel sowie Anschl sse f r Brennstoff und Bedie...

Page 15: ...F Stellung Das Heizger t kann nicht sofort erneut gestartet werden bevor die Abk hlphase verstrichen ist und alle Signall mpchen erlochen sind Wenn die Signall mpchen erloschen sind k nnen Sie das Hei...

Page 16: ...wechselnd die am Thermostat eingestellte Temperatur und die Ist Temperatur Thermostat Steuerung Die nderung der Einstellwerte f r Temperatur und Leistung erfolgt ber die Pfeiltasten Um den neuen Wert...

Page 17: ...uch A berechnet Heizleistung kW Verbrauch l h Pumpenfrequenz Kennwort Akkuspannung V Brennertemperatur C Zeit bis zur Reinigung max 500 h Gebrauchszeit h Umgebungstemperatur C Heizmodus Bel ftungsmodu...

Page 18: ...Betriebsschalter wird die Ursache der St rung mittels Signall mpchen angezeigt und die St rung wird durch Abschaltung des Heizger tes quittiert Bevor das Heizger t erneut gestartet wird muss die Ursac...

Page 19: ...sleslang med filter 1 st Monteringsh llare 1 st D mpningsserie Tillbeh rsp sens inneh ll 6 st Skruvar f r monteringsh llare 5 x 16 2 st F stbult M8 x 140 2 st Korrugerat pl tunderlag M8 1 st Slangkl m...

Page 20: ...r v rmaren kan v ljas antingen en Basbrytare baserad p kontrollampor eller en intelligent Infobrytare V rmaren r tillverkad helt i rostfritt material Tabell 1 Tekniska data f r 40D v rmaren e l s n r...

Page 21: ...gnas V rmaren har 2 x 75 mm utbl sningsanslutningar F r att s kra tillr ckligt luftfl de f rdelas uppv rmningsluften med minst fyra spj lverk Av v rmarens 2 x 75 mm insugningsanslutningar monteras den...

Page 22: ...av v rmaren med 2 st M8 l sbrickor och M8 x 140 l sbultar Bild 4 Montering av v rmaren i h llaren Bild 3 Montering av st llningen vid skottet med 4 st 5 x 16 universalskruvar Bild 2 Montage av monter...

Page 23: ...ild 9 Anslutningar f r br nsleslang elkabel och brytare 1 gr n 2 tom 3 ljusr d 4 vit 5 gul 6 brun 7 tom 8 gr 9 bl Bild 10 Kopplingsschema f r magnetventil Bild 8 B de utbl snings och sugslangarnas r r...

Page 24: ...opplas p nytt f rr n efterkylningen har upph rt och alla kontrollampor har slocknat Koppla p v rmaren p nytt i HEAT l ge d kontrollamporna har sl ckts V rmaren kopplas bort genom att brytaren vrids i...

Page 25: ...mostaten och den uppm tta temperaturen termostatstyrning turvis Temperaturens och effektens inst llningsv rde kan ndras med piltangenter Om man vill att det nya v rdet blir utg ngsv rde skall man tryc...

Page 26: ...uk Effekt Inst lln Str m A kalkylm ssig V rme effekt kW Br nsle f rbr l h Pumpfrekvens password Batteri sp nning V Br nnartemp C Tid till service max 500 h Driftstimmar h Rumstemp C V rme Ventilation...

Page 27: ...et terst lls i huvudmenyn P Basbrytaren anger kontrollamporna orsaken till felet och felet terst lls genom att str mmen till v rmaren bryts Orsaken till felet skall alltid utredas och repareras innan...

Page 28: ...hto 4 m Polttoaineletku suodattimella 1 kpl Kiinnitysteline 1 kpl Vaimennussarja Tarvikepussin sis lt 6 kpl Kiinnitystelineen ruuvit 5 x 16 2 kpl Kiinnityspultti M8 x 140 2 kpl Aaltoaluslevy M8 1 kpl...

Page 29: ...in perustuvan Perusk ytt kytkimen tai lykk n Infok ytt kytkimen L mmitin on valmistettu kokonaan ruostumattomista materiaaleista Taulukko 1 Tekniset tiedot 40D l mmittimelle e n i a o t t l o P y j l...

Page 30: ...lle L mmittimen 2 x 75 mm imuliit nn ist ylempi asennetaan ottamaan raitista ulkoilmaa ja alempi veneen sis ilmaa Imuputkien p ihin kiinnitet n kuristusl p tt m t suojaverkot ulkoilmaa imev lle imuau...

Page 31: ...ttimen kiinnitt minen telineeseen Kuva 5 L mmittimen lukitseminen 2 kpl M8 t htialuslevyj ja M8 x 140 lukituspulteilla Kuva 2 Kiinnitystelineen ja vaimennussarjan yhdist minen Tarvittavat ruuvit ovat...

Page 32: ...ston putket kiinnitet n letkusiteill L mmitin imee ilman samasta p dyst jossa on virtajohto polttoaine ja ohjauspaneeli liittimet Kuva 9 Polttoaineletkun virtajohdon ja k ytt kytkimen liit nn t Kuva 1...

Page 33: ...kua k ynnistyksen j lkeen K nn virtakytkin OFF asentoon L mmitint ei voi k ynnist uudelleen ennen kuin j lkij hdytys on loppunut ja kaikki merkkivalot ovat sammuneet Merkkivalojen sammuttua k ynnist l...

Page 34: ...rvittava salasana annetaan vain valtuutetuille Wallas huoltoliikkeille L mmitys P valikon Toiminto valikosta valitaan l mmittimelle l mmitystila L mmitystilassa l mmitin k ynnistet n painamalla ON OFF...

Page 35: ...Virran kulutus A laskennallinen L mmitysteho kW Kulutus l h Pumpun syketaajuus salasana Akun j nnite V Poltinl mp tila C Aika puhdistukseen max 500 h K ytt tunnit h Huonel mp tila C L mmitystila Tuule...

Page 36: ...l l a h u p i t n i o t s a m l i i a t n i l l a h u p o l a p a p p l u t u k h e H u u k k i v n e n i a n u P _ _ _ _ _ _ _ _ Huolto L mmittimen teknisten osien huollossa noudatetaan yleisohjeen W...

Reviews: