[
IV
Remote Controller ]
- 49 -
HWE15070
GB
Settings details
[4]-1. Display language setting
The display language can be selected from the languages listed below.
• Press the [
MENU] button to change the language.
English (GB),
German (D),
Spanish (E),
Russian (RU),
Italian (I),
French (F),
Swedish (SW)
[4]-2. Function lock settings
(1) Function lock
• Press the [
ON/OFF] button to toggle through the following options.
*
Press and hold the [CIR.WATER] and [
ON/OFF] buttons
simultaneously for two seconds on the Normal Operation screen to enable
the button-lock function.
(2) Operation mode skip setting
The following modes can be made available for selection or can be hidden.
• Press the [
ON/OFF] button to toggle through the following options.
*
The mode that is not supported on the connected unit will not be available,
even if the mode is available for selection on the display.
(3) Temperature range limit setting
The temperature range for the following modes can be restricted. Once the
range has been restricted, the preset temperature can only be set to a value
within the restricted range.
• Press the [
ON/OFF] button to toggle through the following options.
• To increase or decrease the temperature, press the [
TEMP.
or
] button.
• Settable range
*
The settable range varies depending on the type of unit to be connected.
[4]-3. Basic functions
(1) Remote controller main/sub setting
• Press the [
ON/OFF] button
to toggle between the following options.
(2) Use of clock setting
• Press the [
ON/OFF] button
to toggle between the following options.
(3) Timer function setting
• Press the [
ON/OFF] button
to toggle through the following options.
*
When the use of clock setting is set to OFF, the “WEEKLY TIMER” cannot
be used.
(4) Contact number setting
• Press the [
ON/OFF] button
to toggle through the following options.
• Setting the contact number
To set the contact number, follow the following procedures.
Press the [
TEMP.
or
] button
to move the cursor to the
right (left). Press the [
CLOCK
or
] button
to set the
contact number.
(5) Temp offset setting
• Press the [
ON/OFF] button
to toggle between the following options.
[4]-4. Display options
(1) Temperature unit °C/°F setting
• Press the [
ON/OFF] button
to toggle between the following options.
(2) Water temperature display setting
• Press the [
ON/OFF] button
to toggle between the following options.
no1: All buttons except the [
ON/OFF] button will be locked.
no2: All buttons will be locked.
OFF (Default): No buttons will be locked.
Heating mode
Heating ECO mode
Hot Water mode
Anti-freeze mode
Cooling mode
OFF (Default): All modes will be available for selection.
LIMIT TEMP HEATING MODE
LIMIT TEMP HOT WATER MODE
LIMIT TEMP ANTI-FREEZE MODE
LIMIT TEMP COOLING MODE
OFF (Default) : The temperature ranges are not active.
Hot Water mode :
Lower limit:
Upper limit:
25 ~70 °C
70 ~25 °C
(77 ~158 °F)
(158 ~ 77 °F)
Heating mode
:
Lower limit:
Upper limit:
25 ~55 °C
55 ~25 °C
(77 ~131 °F)
(131 ~ 77 °F)
Main
The controller will be designated as the main controller.
Sub
The controller will be designated as the sub controller.
ON The
clock
function.
OFF The
clock
function.
WEEKLY TIMER (Default)
SIMPLE TIMER
AUTO OFF TIMER
TIMER MODE OFF
CALL OFF
The contact number will not be displayed when a
problem occurs.
CALL **** *** ****
The contact number will be displayed when a
problem occurs.
CALL_
Use this option to enter the contact number.
ON
The offset value will be displayed under the water
temperature initial setting mode.
OFF
The offset value will not be displayed.
°C
Celcius
°F
Fahrenheit
ON
The water temperature will be displayed.
OFF
The water temperature will not be displayed.
1
2
3
4
5
6
7
1
2
3
1
2
3
4
5
1
2
3
4
5
6
1
2
1
2
1
2
1
2
1
2
1
2
1
2
3
4
D
D
D
D
D
D
D
F
C
0000001906.book 49 ページ 2015年11月5日 木曜日 午前11時55分
Summary of Contents for CAHV-P500YB-HPB
Page 1: ......
Page 7: ...CONTENTS HWE15070 GB ...
Page 9: ... 2 HWE15070 GB ...
Page 19: ... 12 HWE15070 GB ...
Page 37: ... 30 II Restrictions GB HWE15070 ...
Page 39: ... 32 HWE15070 GB ...
Page 48: ... 41 HWE15070 GB IV Remote Controller 1 Using the Remote Controller 43 2 Function Settings 48 ...
Page 49: ... 42 HWE15070 GB ...
Page 57: ... IV Remote Controller 50 HWE15070 GB ...
Page 58: ... 51 HWE15070 GB V Electrical Wiring Diagram 1 Electrical Wiring Diagram 53 ...
Page 59: ... 52 HWE15070 GB ...
Page 65: ... 58 V Electrical Wiring Diagram GB HWE15070 ...
Page 67: ... 60 HWE15070 GB ...
Page 71: ... VI Refrigerant Circuit 64 HWE15070 GB ...
Page 73: ... 66 HWE15070 GB ...
Page 111: ... 104 HWE15070 GB ...
Page 117: ... VIII Test Run Mode 110 HWE15070 GB ...
Page 119: ... 112 HWE15070 GB ...
Page 163: ... IX Troubleshooting 156 HWE15070 GB ...
Page 164: ... 157 HWE15070 GB X Attachments 1 R407C saturation temperature table 159 ...
Page 165: ... 158 HWE15070 GB ...
Page 167: ... X Attachments 160 HWE15070 GB ...
Page 168: ......