background image

Reference Manual 

Cosy XL 

Double 

 

CANADA & USA MODEL HEATERS: 

SCOSYXL230120   (120V - 1500W (TOTAL: 3000W)) 
SCOSYXL230240   (208 / 240V - 1125 / 1500W (TOTAL: 2250 / 3000W)) 
SCOSYXL240240   (208 / 240V - 1500 / 2000W (TOTAL: 3000 / 4000W))

 

WEATHERPROOF INFRARED HEATERS 

SUITABLE FOR OUTDOOR AND INDOOR USE - 

RESIDENTIAL, COMMERCIAL AND INDUSTRIAL 

INFORESIGHT CONSUMER PRODUCTS INC.

 

125 Traders Blvd. E Unit # 4, Mississauga, Ontario L4Z 2H3 

Tel: 905-568-7655  -  Fax: 905-568-7521 

Email: [email protected]  -  Website: www.solairaheaters.com 

247748 

I M P O R TA N T   -   S AV E   T H E S E   I N S T R U C T I O N S   F O R   F U T U R E   R E F E R E N C E  

E

N

 

Summary of Contents for SCOSYXL-3000

Page 1: ...2000W TOTAL 3000 4000W WEATHERPROOF INFRARED HEATERS SUITABLE FOR OUTDOOR AND INDOOR USE RESIDENTIAL COMMERCIAL AND INDUSTRIAL INFORESIGHT CONSUMER PRODUCTS INC 125 Traders Blvd E Unit 4 Mississauga Ontario L4Z 2H3 Tel 905 568 7655 Fax 905 568 7521 Email info solairaheaters com Website www solairaheaters com 247748 IMPORTANT SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE EN ...

Page 2: ...volt heater when not in use or if hard wired disconnect the supply 6 Do not operate any heater with a damaged cord or after the heater malfunctions has been dropped or damaged in any manner Return heater to authorized service facility for examination electrical or mechanical adjustment or repair 7 This heater is not intended for use in bathrooms laundry areas and similar locations Never locate hea...

Page 3: ...areas where gasoline paint or flammable liquids are used or stored 14 Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire 15 Do not cover or otherwise obstruct the heater 16 Do not touch the heater during operation as the body becomes very hot and cause burns Particular attention has been given where children and vulnerable people are present IMPORTA...

Page 4: ...ded 5 WARNING Keep the mains cords away from the body of the heater which will get hot during use 6 If a socket outlet is used do not position the outlet immediately behind the heater 7 Avoid the use of an extension cord with this product 8 Do not cover or obstruct the heater while it is in use 9 Do not insert any object through any slot or opening in the heater 10 Do not use if guard is not prese...

Page 5: ...G RISK OF FIRE WARNING RISK OF FIRE SPECIFICATION T a b l e 1 C a n a d a a n d U S A H e a t e r s INSTALL ATION The 120V version of the heater is fitted with 2 supply cords measuring 180 inches 500 cm and has molded 3 pin 15 amp plugs The 208 240V version of the heater is fitted with 2 supply cords measuring 79 inches 200 cm for hard wiring WARNING Wiring procedures and connections should be in ...

Page 6: ...ody or obstructing the air vents HORIZONTAL MOUNTING Fig A Fig B Fig C MIN 45 98 in 250 cm GROUND LEVEL INDENT PREVENTS DROP DOWN MOVEMENT CAUTION CAUTION CAUTION CAUTION MOUNTING Switch off unplug the heater from the mains supply when mounting or adjusting the heater position CAUTION When mounting the heater do not position the heater at an angle more than 50 or less then 45 as shown in Fig A CAU...

Page 7: ...ontact your local distributor quoting model type and rating from rating label It is very important that your replacement emitter is exactly the same as the one it was supplied with Failure to fit the exact same type can cause the heater to prematurely fail Fig D CAUTION Please ensure that the length of wires on the replacement emitter s are the same as shown in the diagram below Fig D The sleeves ...

Page 8: ... the emitter Contact your distributor for the correct replacement quoting model type and rating from rating label We recommend you read through the procedure and refer to the parts diagram on the back page of this manual before commencing work REPLACING THE EMITTER 4 Disconnect the emitter wires from the connector blocks by unscrewing the screws highlighted above in Fig 2 5 Unscrew the four screws...

Page 9: ... emitter the wire will be clearly visible in the emitter wire tube so gently pull the wire Fig 6 out of the tube until it is free 10 One at a time pull the spring clips back in the direction shown in Fig 7 and lift up the ceramic caps of the emitter to remove it from the heater 11 The emitter should now be removed from the heater 12 Refit the new emitter s in reverse order ensuring the ceramic cap...

Page 10: ...L4Z 2H3 Tel 905 568 7655 Fax 905 568 7521 Email info solairaheaters com Website www solairaheaters com Due to our policy of ongoing improvement we reserve the right to make changes without notice 2013 INFORESIGHT CONSUMER PRODUCTS INC Ref No 042229 Issue No 1 247748 IMPORTANT SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE ...