NV5100MC Master Control • Reference Man ual
147
7. Other MC Products
Emergency Bypass Control Panel
Figure 7-2 shows the connection between the EBCP and the auxiliary port of the MCE, MPCM-
SD, -HD, -HD2, -SDHD:
Figure 7 -2. EBCP Connections to DB25 of MCPM-SD, -HD, -HD2, and -SDHD
Figure 7-3 shows the connection between the EBCP and MPCM-MK-SD or -MK-HD aux ports:
Figure 7 -3. EBCP Connections to DB15 of MCPM-MK-SD and MCPM-MK-HD
Configuration
The MCPM must be configured to allow its GPI inputs to control the emergency bypass relay for
use with the EBCP. The MCPM configuration software lets you specify one of 5 behaviors for each
GPI input. In conjunction with the cabling of figures 7-2 or 7-3, make the following settings:
For GPI2, choose ‘Set Emergency Bypass Relay to Normal’.
For GPI1, choose ‘Set Emergency Bypass Relay to Bypass’.
Refer to the
MasterConfig User’s Guide
for configuration details.
1
5
6
9
1
13
14
25
MCPM Aux
EBCP
EBCP
MCPM
Pin
Function
Function
Pin
1
n.c.
n/a
—
2
Bypass COM
Common relay contact
2
3
GND
GPI2–
6
4
Red Switch Out
GPI1+
7
5
n.c.
n/a
—
6
Bypass NO
Normally open relay contact
14
7
Green Switch Out
GPI2+
18
8
n.c.
n/a
—
9
GND
GPI1–
20
1
5
6
9
1
8
9
15
MCPM Aux
EBCP
EBCP
MCPM
Pin
Function
Function
Pin
1
n.c.
n/a
—
2
Bypass COM
Common relay contact
13
3
GND
GPI2–
10
4
Red Switch Out
GPI1+
1
5
n.c.
n/a
—
6
Bypass NO
Normally open relay contact
5
7
Green Switch Out
GPI2+
2
8
n.c.
n/a
—
9
GND
GPI1–
9
Summary of Contents for NV5100MC Master Control
Page 14: ...xiv Rev 2 10 17 Feb 11 Table of Contents ...
Page 54: ...40 Rev 2 10 17 Feb 11 3 Frames Other Modules ...
Page 92: ...78 Rev 2 10 17 Feb 11 4 MCPMs Other General Features ...
Page 112: ...98 Rev 2 10 17 Feb 11 5 MCEs Summary ...
Page 158: ...144 Rev 2 10 17 Feb 11 6 Control Panels Aux Preview GUI ...
Page 166: ...152 Rev 2 10 17 Feb 11 7 Other MC Products Device Controller ...
Page 224: ...210 Rev 2 10 17 Feb 11 C Misc Information NorthAmerican andInternational PowerCords ...
Page 240: ...226 Rev 2 10 17 Feb 11 Index ...