NV5100MC Master Control • Reference Man ual
177
B. Specifications
Frames
EM0414 Jumpers
The EM0414 clock generator card also has several jumper sets:
Figure B-2. EM0414 Clock Generator Card Jumpers
Table B-13 describes the jumpers. Jumpers not listed should be left in the factory position:
J13
AESREF2
J16
AESREF1
Set impedance jumpers (J13, J16) as follows:
For Phoenix 110
W
, place both jumpers on the upper 4 pins.
For BNC 75
W
place both jumpers on the middle 4 pins.
For Phoenix Hi-Z, place both jumpers on the bottom 4 pins.
For BNC Hi-Z, set the left jumper on the bottom 2 pins and
set the right jumper on the middle 2 pins
LED7
LED8
LED9
SICK
ACTIVE
HEALTH
J13
AESREF2
J16
AESREF1
RUN_PLL
J22
SET_FREQ
RUN_PLL
SET_FREQ
J22
Table B-13. EM0414 Jumpers
Jumper
Settings
J13, J16
AES reference termination options. See Figure B-2 for jumper settings. (The settings are the
same for the EM0374 and EM0414.)
J22
Leave this jumper in the RUN_PLL position.