38
25. When a steady stream of syrup is flowing from the
syrup valve and all air has been purged from the
syrup line, press any syrup Flavor symbol
to stop
the pump.
26.
Repeat steps 23 and 24
to prime the rest of the
syrup lines. After priming is complete, exit the Syrup
Prime mode by pressing the Calibrate symbol
.
27. Using the squeeze bottle filled with sanitizing
solution, sanitize the syrup valve nose fittings.
28. Lubricate the O-ring. Raise the syrup valve retainer.
Install the syrup valve. Push the syrup valve retainer
down to hold the valve in place.
Repeat this procedure
for each syrup valve.
Figure-37
Note:
Do not install an empty syrup line in the freezer
door. Insert a syrup port plug in the door whenever a
syrup line is not in use. This will prevent an accumulation
of mix inside the valve fitting and the syrup line.
29. Using a clean, sanitized towel, wipe down the freezer
door, front panel, the area around the bottom of the
freezer door, and any other areas that show a buildup
of either moisture or food substance.
30. Use a clean, damp, sanitized towel to gently wipe the
portion control sensor shield and remove any mix
buildup. Inspect the sensor shield for damage and
replace if necessary. (See Figure-38.)
Figure-38
31. Install the shake cup holder, front drip tray, and
splash shield.
32. When ready to resume normal operation, press the
Auto symbol
. (See Figure-39.) The control has a
feature in the Manager's Menu to enable or disable
the Auto Start feature. When Auto Start is enabled,
the machine will automatically exit the Standby mode
and start both sides in the Auto mode at a designated
time each day. (see page 80.)
Figure-39
Note:
The machine should be placed in Auto mode
approximately 15 minutes prior to serving product.
Summary of Contents for C602
Page 2: ......
Page 9: ...7 Front View Figure 2 1 2 3 4 5 7 7a 10 11 8 8 9 7c 7b 6 12 13 14 ...
Page 21: ...19 Beater Door Assembly Shake Side Figure 11 6 4 1 3 2 5 17 11 13 12 7 8 10 9 14 15 16 ...
Page 23: ...21 Beater Door Assembly Soft Serve Side Figure 12 2 3 11 4 5 12 13 1 14 15 16 6 8 7 6 9 10 ...
Page 25: ...23 X53800 BRN TAN Syrup Pump Figure 13 3 4 2g 5 1 2e 2f 2d 2c 2a 2b 2 2h ...
Page 114: ...057888 M ...