12. Remove the cotter pin from the pump. Stand the mix
feed tube in the corner of the mix hopper. Place the
cotter pin in position in the outlet fitting of the pump.
(See Figure-166.)
Figure-166
Note:
You have just sanitized all the food contact
surfaces of the freezer.
Priming—Shake Side
Note:
Use only
fresh
mix when priming the freezer.
1. With a pail beneath the door spout, press any Flavor
Selection symbol
to open the draw valve. Pour
2-1/2 gal. (9.5 L) of
fresh
mix into the mix hopper and
allow it to flow into the freezing cylinder. This will
force out any remaining sanitizing solution. When
full-strength mix is flowing from the door spout, press
any Flavor Selection symbol
to close the draw
valve.
Important!
Failure to remove all sanitizing solution may
damage the freezing cylinder.
2. When the mix stops bubbling down into the freezing
cylinder, remove the cotter pin from the outlet fitting
of the mix pump. Insert the outlet end of the mix feed
tube into the mix inlet hole in the mix hopper. Place
the inlet end of the mix feed tube into the outlet fitting
of the mix pump. Secure with cotter pin.
Figure-167
3. Install the shake cup holder. (See Figure-168.)
Figure-168
4. Select the Auto symbol
.
5. Fill the hopper with
fresh
mix and place the mix
hopper cover in position.
Priming—Soft Serve Side
Note:
Use only
fresh
mix when priming the freezer.
1. With a pail beneath the door spout, open the draw
valve. Pour 2-1/2 gal. (9.5 L) of
fresh
mix into the mix
hopper and allow it to flow into the freezing cylinder.
This will force out any remaining sanitizing solution.
When full-strength mix is flowing from the door spout,
close the draw valve.
Important!
Failure to remove all sanitizing solution may
damage the freezing cylinder.
Summary of Contents for C602
Page 2: ......
Page 9: ...7 Front View Figure 2 1 2 3 4 5 7 7a 10 11 8 8 9 7c 7b 6 12 13 14 ...
Page 21: ...19 Beater Door Assembly Shake Side Figure 11 6 4 1 3 2 5 17 11 13 12 7 8 10 9 14 15 16 ...
Page 23: ...21 Beater Door Assembly Soft Serve Side Figure 12 2 3 11 4 5 12 13 1 14 15 16 6 8 7 6 9 10 ...
Page 25: ...23 X53800 BRN TAN Syrup Pump Figure 13 3 4 2g 5 1 2e 2f 2d 2c 2a 2b 2 2h ...
Page 114: ...057888 M ...